2018
DOI: 10.1016/j.jallcom.2018.01.205
|View full text |Cite
|
Sign up to set email alerts
|

One-pot synthesis of Au-Cu2O/rGO nanocomposite based electrochemical sensor for selective and simultaneous detection of dopamine and uric acid

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
36
1

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 188 publications
(39 citation statements)
references
References 50 publications
2
36
1
Order By: Relevance
“…The analytical performances were compared to those in previous works (Table 1). Obviously, the sensing parameters of the proposed sensor are comparable to, or even better than, previously reported modified electrodes [7,46,47,48,49,50,51,52,53,54].…”
Section: Resultssupporting
confidence: 74%
See 2 more Smart Citations
“…The analytical performances were compared to those in previous works (Table 1). Obviously, the sensing parameters of the proposed sensor are comparable to, or even better than, previously reported modified electrodes [7,46,47,48,49,50,51,52,53,54].…”
Section: Resultssupporting
confidence: 74%
“…As another critical biomolecule in human body, UA is commonly regarded as the metabolic product of purine [6]. Generally, the UA level is 4.1 ± 8.8 mg/100 mL for a healthy individual [7]. The abnormal concentration of UA in physiological fluids likely leads to several disorders including pneumonia, hyperuricemia, and gout [8].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…The anodic peak current increases linearly with the increasing concentration of UA with a correlation co-efficient of R 2 = 0.9987. Table 2 shows the electroanalytical parameters of the γ-Fe 2 O 3 nanobelts/GCE based DA sensor were compared with other modified electrodes [56][57][58][59][60][61][62][63][64]. It can be seen that the γ-Fe 2 O 3 nanobelts/GCE exhibited wider linear range and lower detection limit in comparison with other electrochemical sensing platforms.…”
Section: Effect Of Ua Concentration On the γ-Fe2o3 Nanobelts/gcementioning
confidence: 99%
“…PTCA-RGO-MWCNTsÀ Au NPs/ GCE 1-100 0.124 μA mM À 1 0.07 [44] Gold nanosheets/ GCE 2-298 7 μA mM À 1 0.28 [45] Au-Cu 2 O/rGO/GCE 10-90 -3.9 [46] Au@ZIF-8/GCE 0.1-50 6.452μA mM À 1 cm À 2 0.01 [47] K 2 Fe 4 O 7 /GCE 1-40, 40-140 0.22 [48] Fe 2 NiMIL-88B/GCE 1.2-1800…”
Section: Anti-interference Reproducibility and Stability Studymentioning
confidence: 99%