2017
DOI: 10.20998/2074-272x.2017.4.09
|View full text |Cite
|
Sign up to set email alerts
|

Online Technological Monitoring of Insulation Defects in Enameled Wires

Abstract: In this paper the authors used non-destructive technological monitoring of defects insulation enameled wire with poliimid polymer. The paper is devoted to the statistical method for processing, comparison and analysis of results of measurements of parameters of insulation of enameled wire because of mathematical model of trend for application in active technological monitoring is developed; the recommendations for parameters of such monitoring are used. It is theoretically justified and the possibility of dete… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
3
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
3

Relationship

2
1

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 2 publications
0
3
0
Order By: Relevance
“…Problem definition. The introduction of enameled wires based on poliimide synthetic copolymers with a temperature index of 200 ºC, which have the highest modern level of electrical, mechanical strength and minimum thickness of insulation [1,2], encountered contradictions characteristic of innovation in cable products. This is a contradiction between the relatively high cost of products and the need to organize the use of advanced state-of-the-art monitoring technologies.…”
Section: представлены результаты определения напряжения пробоя изоляцmentioning
confidence: 99%
See 1 more Smart Citation
“…Problem definition. The introduction of enameled wires based on poliimide synthetic copolymers with a temperature index of 200 ºC, which have the highest modern level of electrical, mechanical strength and minimum thickness of insulation [1,2], encountered contradictions characteristic of innovation in cable products. This is a contradiction between the relatively high cost of products and the need to organize the use of advanced state-of-the-art monitoring technologies.…”
Section: представлены результаты определения напряжения пробоя изоляцmentioning
confidence: 99%
“…Analysis of literature. The first works devoted to the tasks of technological monitoring, dated from the beginning of 60-ies of the twentieth century, and the result is formulated in [5], where the main thing is that in the very formulation of the question of technological monitoring, it was recorded the possibility of changes in the technological process and the need to identify and quantify these changes [1]. In theory, this means that each measurement result is an element of an unknown statistical array.…”
Section: представлены результаты определения напряжения пробоя изоляцmentioning
confidence: 99%
“…Analysis of literature. Cable production is characterized by significant lengths of products with high requirements for the uniformity of length parameters, therefore the value of Ř per unit of length is standardized [2]. The monitoring of homogeneity of R in length is the subject of technological monitoring.…”
Section: представлены результаты контроля электрического сопротивлениmentioning
confidence: 99%