2014
DOI: 10.1371/journal.pone.0106881
|View full text |Cite
|
Sign up to set email alerts
|

Open Tubular Lab-On-Column/Mass Spectrometry for Targeted Proteomics of Nanogram Sample Amounts

Abstract: A novel open tubular nanoproteomic platform featuring accelerated on-line protein digestion and high-resolution nano liquid chromatography mass spectrometry (LC-MS) has been developed. The platform features very narrow open tubular columns, and is hence particularly suited for limited sample amounts. For enzymatic digestion of proteins, samples are passed through a 20 µm inner diameter (ID) trypsin + endoproteinase Lys-C immobilized open tubular enzyme reactor (OTER). Resulting peptides are subsequently trappe… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0
7

Year Published

2015
2015
2023
2023

Publication Types

Select...
5
1

Relationship

1
5

Authors

Journals

citations
Cited by 37 publications
(34 citation statements)
references
References 56 publications
1
26
0
7
Order By: Relevance
“…Digestion of proteins into MS-friendly peptides is generally carried out and subsequent analysis is done by LC-MS, which is one of the best techniques for proteomics, and it requires the development of high resolution LC columns to separate as many peptides as possible [3]. Monolithic columns [4], columns based on fused core particles [5], and UHPLC columns [6][7][8] are some examples of novel chromatographic approaches of attracted interest.…”
Section: Introductionmentioning
confidence: 99%
“…Digestion of proteins into MS-friendly peptides is generally carried out and subsequent analysis is done by LC-MS, which is one of the best techniques for proteomics, and it requires the development of high resolution LC columns to separate as many peptides as possible [3]. Monolithic columns [4], columns based on fused core particles [5], and UHPLC columns [6][7][8] are some examples of novel chromatographic approaches of attracted interest.…”
Section: Introductionmentioning
confidence: 99%
“…OT têm um consumo extremamente baixo de solventes, e permite maior sensibilidade ao usar espectrometria de massas por ionização por electrospray (ESI-MS) (93). OT colunas têm recebido atenção devido à sua bem sucedida cromatografia de compostos de elevada massa molecular, tais como proteínas e peptídeos com alta capacidade de pico em sistemas de alta sensibilidade nano-LC tandem MS (MS / MS) (32,92,94,95,96,97). No entanto, as colunas do tipo OT estão associadas a uma fraca retenção e é praticamente não favorável para a análise de moléculas pequenas, o que está muito mais associado a colunas maiores e de alta capacidade.…”
Section: Colunas Plotunclassified
“…Para permitir a injeção de μL de amostras (isto é, capacidade superior) em colunas OT, pode ser utilizada a SPE em linha. Apenas um número limitado de estudos exploraram variantes de coluna SPE para acoplamento OT (32,33,92,94,95,96,97,100,101).…”
Section: Colunas Plotunclassified
See 2 more Smart Citations