2018
DOI: 10.1039/c8re00046h
|View full text |Cite
|
Sign up to set email alerts
|

OpenFlowChem – a platform for quick, robust and flexible automation and self-optimisation of flow chemistry

Abstract: OpenFlowChem – an open-access platform for automation of process control and monitoring optimised for flexibility.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
67
0
1

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
2

Relationship

1
6

Authors

Journals

citations
Cited by 62 publications
(69 citation statements)
references
References 71 publications
1
67
0
1
Order By: Relevance
“…To avoid any potential high correlation between the preexponential factor, k 0 (units are either min −1 or L mol −1 min −1 depending on if the reaction is 1 st or 2 nd order), and activation energy, E a (J mol −1 ), the Arrhenius expression was written in the parameterised form shown in eqn (14), as this is shown to give the most accurate results and lead to fewer numerical problems during both parameter estimation and experiment design. 69…”
Section: Kinetic Modelmentioning
confidence: 99%
See 3 more Smart Citations
“…To avoid any potential high correlation between the preexponential factor, k 0 (units are either min −1 or L mol −1 min −1 depending on if the reaction is 1 st or 2 nd order), and activation energy, E a (J mol −1 ), the Arrhenius expression was written in the parameterised form shown in eqn (14), as this is shown to give the most accurate results and lead to fewer numerical problems during both parameter estimation and experiment design. 69…”
Section: Kinetic Modelmentioning
confidence: 99%
“…A similar approach was reported in the literature for a GC system which also did not provide instrument drivers. 14 One of the major issues of autonomous systems is that they are task-specific and that small changes in the experimental set-up require significant work to update the system. This can lead to situations where it is faster to conduct experiments manually than to develop automation algorithms for each new version of an experimental set-up.…”
Section: Integration Of Python Scripts In Labviewmentioning
confidence: 99%
See 2 more Smart Citations
“…The reactor was operated autonomously executing a pre-defined reaction program and injecting liquid samples into vials equipped with septa to minimize sample evaporation. 40 The samples were taken after the time required for the liquid to displace at least 3 times the reactor volume before collecting 3-4 samples for every set of reaction conditions. The liquid samples collected were analyzed by the GC with the response factors related to tetradecane and calibrated using a series of reference solutions for every compound.…”
Section: Hydrogenation Experimentsmentioning
confidence: 99%