2020
DOI: 10.1016/j.injury.2020.06.026
|View full text |Cite
|
Sign up to set email alerts
|

Operative treatment of 2-part surgical neck type fractures of the proximal humerus in the elderly: Cement augmented locking plate PHILOS™ vs. proximal humerus nail multiloc®

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

2
13
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 24 publications
(15 citation statements)
references
References 39 publications
2
13
0
Order By: Relevance
“…Hessmann et al reported good results after antegrade fixation with a straight design nail at short term follow up (6 months) with a mean Constant-Murley score of 66.1, mean forward flexion of 134° and mean abduction of 125° and with a 100% of radiographic healing [ 23 ]. Moreover the recent work of Helfen et al demonstrated good functional outcomes using straight design nails in 2-part fractures of the proximal humerus: both functional outcome and radiographic evaluation were satisfactory at 24 months of follow up, comparable to results achieved with the use of a locking plate fixation [ 32 ]. Kloub et al also described satisfactory results of the use of a straight design nail even in 4-part fractures of the proximal humerus: in a cohort of 35 patients at 25,8 months of follow up a relative side related Constant-Murley score of 66.8% was obtained, with only 6 cases of avascular necrosis of the humeral head [ 24 ].…”
Section: Discussionmentioning
confidence: 87%
“…Hessmann et al reported good results after antegrade fixation with a straight design nail at short term follow up (6 months) with a mean Constant-Murley score of 66.1, mean forward flexion of 134° and mean abduction of 125° and with a 100% of radiographic healing [ 23 ]. Moreover the recent work of Helfen et al demonstrated good functional outcomes using straight design nails in 2-part fractures of the proximal humerus: both functional outcome and radiographic evaluation were satisfactory at 24 months of follow up, comparable to results achieved with the use of a locking plate fixation [ 32 ]. Kloub et al also described satisfactory results of the use of a straight design nail even in 4-part fractures of the proximal humerus: in a cohort of 35 patients at 25,8 months of follow up a relative side related Constant-Murley score of 66.8% was obtained, with only 6 cases of avascular necrosis of the humeral head [ 24 ].…”
Section: Discussionmentioning
confidence: 87%
“…The Multiloc intramedullary nail adds to the calcar screw design to provide better support for patients with large proximal medial cortical defects [ 19 ]. Several previous studies demonstrated the biomechanical advantages of the intramedullary nail [ 14 16 , 20 ]. There is a high risk of secondary displacement and fracture nonunion in elderly patients with poor bone quality.…”
Section: Discussionmentioning
confidence: 99%
“…Proximal humeral fracture (PHF) affects patient health and is the third most common fracture in the elderly [ 1 , 2 ]. As population demographics continue to change, the incidence of proximal humeral fracture is expected to increase by 50% in 2030 [ 3 ]. Osteoporotic fractures are characterized by loss of bone mass and deterioration of bone microarchitecture and have put a great burden on medical expenses [ 4 , 5 ].…”
Section: Introductionmentioning
confidence: 99%