2008
DOI: 10.1117/12.822507
|View full text |Cite
|
Sign up to set email alerts
|

Optical characteristics of aerosol determined by Cimel, Prede, and Microtops II sun photometers over Belsk, Poland

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

3
7
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 12 publications
(10 citation statements)
references
References 8 publications
3
7
0
Order By: Relevance
“…The deviation is higher at 440 nm and lower at 870 nm in good agreement with previous comparisons of AOD between Prede (elaborated by SKYNET) and Cimel (elaborated by AERONET) (Sano et al, 2003;Evgenieva et al, 2008;Campanelli et al, 2004b). It is also in very good agreement with our previous findings involving direct sun measurements only (Estellés et al, 2010(Estellés et al, , 2012.…”
Section: Optical and Radiative Propertiessupporting
confidence: 80%
“…The deviation is higher at 440 nm and lower at 870 nm in good agreement with previous comparisons of AOD between Prede (elaborated by SKYNET) and Cimel (elaborated by AERONET) (Sano et al, 2003;Evgenieva et al, 2008;Campanelli et al, 2004b). It is also in very good agreement with our previous findings involving direct sun measurements only (Estellés et al, 2010(Estellés et al, , 2012.…”
Section: Optical and Radiative Propertiessupporting
confidence: 80%
“…The calibration drift found in any wavelength channel is adjusted at the time of calibration by changing the irradiance calibration factors for that channel to maintain the accuracy. Moreover, the Microtops-measured spectral AODs have been found in very good agreement with the measurements using other radiometers such as Cimel [e.g., Evgenieva et al, 2008;Giles et al, 2011], Prede [e.g., Evgenieva et al, 2008], MFRSR (Multi-Filter Rotating Shadowband Radiometer), and multi-wavelength solar radiometer [Kompalli et al, 2010]. In the present study, the AOD data for only four wavelengths (340, 500, 870, and 1020 nm), which are common to both the Microtops, have been used.…”
Section: Measurement Site Instrument and Datasupporting
confidence: 70%
“…9), but the coefficient of determination (R 2 ) remains high at around 0.95 for all wavelengths. Previous (unpublished) comparisons between Microtops and CIMEL CE318 resulted in an RMSE of between 0.01 and 0.02; an agreement to within 10 % between Microtops, CIMEL and POM instruments has been reported in Poland under a variety of conditions (Evgenieva et al, 2008). However, the previous studies alluded to above have been for land-based observations and therefore no uncertainties due to the platform motion are present.…”
Section: Corrected Aerosol Optical Depth Comparisonsmentioning
confidence: 64%