2004
DOI: 10.1103/physrevlett.93.147406
|View full text |Cite
|
Sign up to set email alerts
|

Optical Transition Energies for Carbon Nanotubes from Resonant Raman Spectroscopy: Environment and Temperature Effects

Abstract: This Letter reports the laser energy dependence of the Stokes and anti-Stokes Raman spectra of carbon nanotubes dispersed in aqueous solution and within solid bundles, in the energy range 1.52-2.71 eV. The electronic transition energies (E(ii)) and the radial breathing mode frequencies (omega(RBM)) are obtained for 46 different (18 metallic and 28 semiconducting) nanotubes, and the (n,m) assignment is discussed based on the observation of geometrical patterns for E(ii) versus omega(RBM) graphs. Only the low en… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

62
753
9
3

Year Published

2006
2006
2016
2016

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 627 publications
(827 citation statements)
references
References 12 publications
62
753
9
3
Order By: Relevance
“…The RBM frequencies found for the (8,8), (7,7), and (6,6), are 219, 248, and 287 cm −1 , respectively and match those found in previous work 7,19,20,26,27 . The (5,5) RBM frequency is found here to be 338 cm −1 .…”
Section: Resultssupporting
confidence: 77%
See 1 more Smart Citation
“…The RBM frequencies found for the (8,8), (7,7), and (6,6), are 219, 248, and 287 cm −1 , respectively and match those found in previous work 7,19,20,26,27 . The (5,5) RBM frequency is found here to be 338 cm −1 .…”
Section: Resultssupporting
confidence: 77%
“…The (5,5) RBM frequency is found here to be 338 cm −1 . The observed frequencies are fit well by the typical empirical relation relating the frequency (ω RBM ) to the tube diameter, d t , such that ω RBM = A/d t + B, with A and B given as 216±4 cm −1 nm and 21±4 cm −1 , respectively 26,27 .…”
Section: Resultsmentioning
confidence: 98%
“…To determine whether the original chiralities were preserved during the cloning process, we used micro-Raman to characterize the pristine and cloned SWCNTs. For the (7,6) case, we used 1.96 eV laser excitation, which is close to the second optical transition E 22 ¼ 1.92 eV of the (7, 6) nanotubes 28 . To further enhance the signal-to-noise ratio, surface-enhanced Raman spectroscopy was used after e-beam evaporation of 5 nm silver on the substrate (Supplementary Fig.…”
Section: Resultsmentioning
confidence: 99%
“…It shows the (n,m) SWNT configuration for the tubes, which energies E ii are in resonance with the laser line. Raman measurements at a different wavelength can provide detailed information on diameter distribution in the sample [193].…”
Section: Raman Spectroscopymentioning
confidence: 99%