International Conference on Electric Railways in a United Europe 1995
DOI: 10.1049/cp:19950179
|View full text |Cite
|
Sign up to set email alerts
|

Optimal operation of the Swedish railway electrical system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
48
0

Year Published

2007
2007
2020
2020

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 24 publications
(48 citation statements)
references
References 0 publications
0
48
0
Order By: Relevance
“…Even with a very simple control, such as the one used in rotating converters in Scandinavia today (Abrahamsson, 2008;Olofsson, 1996Olofsson, , 1993, where the voltage is adjusted downwards from unity for reactive power production on the catenary side, and conversely upwards for reactive power consumption on the catenary side; the loss profile would theoretically be better than with pure transformer feeding. Rotary converters allow much more flexible control of active and reactive power than this.…”
Section: Voltage Controlmentioning
confidence: 99%
“…Even with a very simple control, such as the one used in rotating converters in Scandinavia today (Abrahamsson, 2008;Olofsson, 1996Olofsson, , 1993, where the voltage is adjusted downwards from unity for reactive power production on the catenary side, and conversely upwards for reactive power consumption on the catenary side; the loss profile would theoretically be better than with pure transformer feeding. Rotary converters allow much more flexible control of active and reactive power than this.…”
Section: Voltage Controlmentioning
confidence: 99%
“…For details of how the Swedish railway power supply system is constituted and can be simulated, please refer to [8], [25]- [27].…”
Section: Comparative Case Studiesmentioning
confidence: 99%
“…The characteristics of rotary and rotary-mimicking converters are given in e.g. [30], [31]. The voltage is controlled so that it is constant or slightly decreasing with increasing reactive load.…”
Section: Modellingmentioning
confidence: 99%
“…In converter stations with several converters of the same kind, P G , Q G , and Q 50 (the total active, reactive, and 50 Hz side reactive power generations, respectively) can simply be divided by the number of converters, # conv , in order to give the proper U and ψ values [6].…”
Section: Electrical and Mechanical Power For Each Time Stepmentioning
confidence: 99%
“…The phase shift on the 50 Hz side of the converter due to train power consumption is, according to [6],…”
Section: Electrical and Mechanical Power For Each Time Stepmentioning
confidence: 99%