2019
DOI: 10.1109/tia.2019.2938918
|View full text |Cite
|
Sign up to set email alerts
|

Optimal Power Flow Incorporating Frequency Security Constraint

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
24
0

Year Published

2021
2021
2025
2025

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(24 citation statements)
references
References 32 publications
0
24
0
Order By: Relevance
“…For that, the authors determined the minimum system damping empirically relying on the load-frequency sensitivity index. Moreover, frequency stability constraints have also been proposed in planning and operation studies of large ACPSs, such as optimal power flow problems, by Wen et al (2016); Abhyankar et al (2017); Geng et al (2017); and Nguyen et al (2019).…”
Section: Introductionmentioning
confidence: 99%
“…For that, the authors determined the minimum system damping empirically relying on the load-frequency sensitivity index. Moreover, frequency stability constraints have also been proposed in planning and operation studies of large ACPSs, such as optimal power flow problems, by Wen et al (2016); Abhyankar et al (2017); Geng et al (2017); and Nguyen et al (2019).…”
Section: Introductionmentioning
confidence: 99%
“…The minimum inertia required by the system to maintain frequency stability in the event of a disturbance is discussed in this section. The equation for frequency deviation can be developed from the LFC model of multi-machine system [29] and is shown in (18).…”
Section: Minimum Inertia Requiredmentioning
confidence: 99%
“…Only one of E c et and E d et would take effect at any particular time, which can be guaranteed by integrating binary indicators (v c et and v d et ) and adding exclusive constraint (8). The stored energy after frequency responses should be subject to the permitted energy ranges in ( 9) and (10), which provides enough energy headroom to sustain frequency responses for the duration time of PFR Δt P . Note that (9) gives out a clear correlation of the stored energy between the normal operation and post-regulation.…”
Section: B Frequency Responses From Bessmentioning
confidence: 99%
“…In recent years, frequency-constrained problems mainly concentrate on optimal operation such as economic dispatch (ED) and unit commitment (UC). For instance, [10] inserts nonlinear frequency deviation constraints into AC optimal power flow (ACOPF) to keep the frequency stability. Considering credible generation outages, [11] takes full usage of primary frequency reserves to satisfy the minimum frequency deviation.…”
Section: Introductionmentioning
confidence: 99%