2014
DOI: 10.1016/j.jfoodeng.2014.02.019
|View full text |Cite
|
Sign up to set email alerts
|

Optimization and modeling of an electrolyzed oxidizing water based Clean-In-Place technique for farm milking systems using a pilot-scale milking system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

1
25
0

Year Published

2015
2015
2020
2020

Publication Types

Select...
4
3
1

Relationship

1
7

Authors

Journals

citations
Cited by 43 publications
(26 citation statements)
references
References 16 publications
1
25
0
Order By: Relevance
“…Electrolyzed water (EW) is seen as a good opportunity to reduce the chemical consumption cost (Dev et al, 2014;Wang et al, 2016). The EW is generated by using the EW generator.…”
Section: Introductionmentioning
confidence: 99%
“…Electrolyzed water (EW) is seen as a good opportunity to reduce the chemical consumption cost (Dev et al, 2014;Wang et al, 2016). The EW is generated by using the EW generator.…”
Section: Introductionmentioning
confidence: 99%
“…CIP is a complex operation which typically involves a warm water rinse, washing with alkaline and/or acidic solution, and a clear rinse with warm water to flush out residual cleaning agents [5]. The CIP efficiency dependents on many factors, such as the type of soil to be removed, the cleaning time, the temperature of the cleaning agent and the favourable hydrodynamic force of the moving liquid [2,6].…”
Section: Introductionmentioning
confidence: 99%
“…1), designated as specimen #4 and 5 at the "downstream locations". Specimen #4 was 147 placed 4.6 m after the return elbow (i.e., 15.6 m from the inlet), and specimen #5 placed 1.2 m M A N U S C R I P T A C C E P T E D ACCEPTED MANUSCRIPT 8 Other components essential to the milking system were also included in the simulator as 152 previously described (Dev et al, 2014), such as a claw with liners, solution sink and receiver jar, 153 vacuum system and milk pump. When conducting CIP, the mean solution slug velocity was 9.1 154 ± 1 m/s and 3 slugs per min and the air entrainment rate was set at 0.12 m 3 /min.…”
mentioning
confidence: 99%
“…The slope of the 158 pipeline in the simulator was set to 0.8% to facilitate gravity draining. 159 The alkaline and acidic EO water solutions were generated using an EO water generator soiling procedure as suggested by our previous study (Dev et al, 2014), i.e., one third (12.7 L) 176 of the raw milk followed by a 10 min air dry, repeated three times. After the soiling was 177 completed, the specimens were dried in an incubator (Model Symphony, VWR international, 178 Radnor, PA), cooled in the desiccator (Model Dry-keeper AutoA-3B, Sanplatec Corp., Osaka, 179 Japan) then weighed using a high precision balance (Model XP504, Mettler-Toledo, LLC., 180 Columbus, OH) with a weighing range of 0 -520 g and a readability of +/-0.0001 g. The 181 deposit mass was determined by subtracting the measured mass of the stainless steel 182 specimen before and after each experiment.…”
mentioning
confidence: 99%
See 1 more Smart Citation