2016
DOI: 10.1016/j.snb.2015.07.098
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of cascaded fiber tapered Mach–Zehnder interferometer and refractive index sensing technology

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
21
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 75 publications
(21 citation statements)
references
References 24 publications
0
21
0
Order By: Relevance
“…The use of fusion splicing, etching, or flame exposure while the fiber is stretched are some of the techniques to prepare tapers. Although some configurations are based on two cascaded tapers, some simple refractometers with just one taper can reach an RI sensitivity up to 1656 nm per RIU . Other configurations based on bent fibers or transitions with core‐mismatch or lateral offsets have also been reported in the last few years, broadening the variety of MZI structures for RI sensing.…”
Section: Refractometers Based On Optical Interferometersmentioning
confidence: 99%
“…The use of fusion splicing, etching, or flame exposure while the fiber is stretched are some of the techniques to prepare tapers. Although some configurations are based on two cascaded tapers, some simple refractometers with just one taper can reach an RI sensitivity up to 1656 nm per RIU . Other configurations based on bent fibers or transitions with core‐mismatch or lateral offsets have also been reported in the last few years, broadening the variety of MZI structures for RI sensing.…”
Section: Refractometers Based On Optical Interferometersmentioning
confidence: 99%
“…The fringe visibility of the MZI with 35 mm PCF, 40 mm PCF and 45 mm PCF were as high as 19.56 dB, 17.78 dB and 23.03 dB, respectively. Those were larger than that of two-taper MZI (17.5 dB) [ 33 ], taper-core-offset section MZI (11.3 dB) [ 34 ], step-like taper MZI (18.64 dB) [ 35 ], normal PCF-MZI (14 dB) [ 23 ]. In addition, the free spectrum range (FSR) would be reduced as the length of MZI increased.…”
Section: Resultsmentioning
confidence: 99%
“…Single parameter measurement was pioneered in [31,32], where the RI and strain were quantified. The following works also achieved curvature [33], lateral stress [34], liquid level [35], and enhanced sensitivity for RI [36] measurements. The aforementioned measurements all employed the widely used peak wavelength shift method, which could be not practical when there is only small difference between the two spectra.…”
Section: Short Tapermentioning
confidence: 99%