2006
DOI: 10.1252/kakoronbunshu.32.477
|View full text |Cite
|
Sign up to set email alerts
|

Optimization of Rotor-Type Solvent Recovery System for Low Concentration Solvent (Optimization with Gas Concentration, Flow Rate Change and Adsorption Deterioration)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2007
2007
2008
2008

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(2 citation statements)
references
References 7 publications
0
2
0
Order By: Relevance
“…As for the thermal swing VOC concentrator, thermal effects for a cyclic adsorption process have been discussed by Ko et al, 8 Gales et al, 9 Sullivan et al, 10 Nastaj et al, 11 and Matsukuma et al 12,13 However, they discussed particle packed beds [8][9][10][11] instead of honeycomb type, a combined temperature-pressure swing 11 or numerical simulation, but not experimental works. [8][9][10][11][12][13] No papers based on experimental data seem available except for a conference paper by Kuma et al 14 and a short paper by Mitsuma et al 15 within the authors' scope. Keller 16 timely outlined the honeycomb rotor adsorber in his review of adsorption technology, but only a few engineering data are published yet, as he said.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…As for the thermal swing VOC concentrator, thermal effects for a cyclic adsorption process have been discussed by Ko et al, 8 Gales et al, 9 Sullivan et al, 10 Nastaj et al, 11 and Matsukuma et al 12,13 However, they discussed particle packed beds [8][9][10][11] instead of honeycomb type, a combined temperature-pressure swing 11 or numerical simulation, but not experimental works. [8][9][10][11][12][13] No papers based on experimental data seem available except for a conference paper by Kuma et al 14 and a short paper by Mitsuma et al 15 within the authors' scope. Keller 16 timely outlined the honeycomb rotor adsorber in his review of adsorption technology, but only a few engineering data are published yet, as he said.…”
Section: Introductionmentioning
confidence: 99%
“…The dehumidifier was applied later to the adsorptive desiccant cooling system, and the heat/mass transfer properties of the dehumidifier itself and the cooling system have been analyzed by Kodama et al, Okano et al, and Jin et al Recently, Matsukuma et al , analyzed a potential application of the honeycomb rotor adsorber to CO 2 recovery other than dehumidification. As for the thermal swing VOC concentrator, thermal effects for a cyclic adsorption process have been discussed by Ko et al, Gales et al, Sullivan et al, Nastaj et al., and Matsukuma et al , However, they discussed particle packed beds 8-11 instead of honeycomb type, a combined temperature-pressure swing 11 or numerical simulation, but not experimental works. No papers based on experimental data seem available except for a conference paper by Kuma et al and a short paper by Mitsuma et al within the authors' scope. Keller timely outlined the honeycomb rotor adsorber in his review of adsorption technology, but only a few engineering data are published yet, as he said.…”
Section: Introductionmentioning
confidence: 99%