2000
DOI: 10.1080/104732200301296
|View full text |Cite
|
Sign up to set email alerts
|

Optimized Portable Cordless Vacuum Method for Sampling Dry, Hard Surfaces for Dusts

Abstract: Surface sampling in industrial/environmental hygiene is a growing field that needs validated standardized methods. There are few standard methods, one being the American Society for Testing and Materials (ASTM) method involving a portable, cordless air sampling pump. In the present work, the ASTM technique was modified to increase efficiency and versatility. A soil sample was first dried and sieved. Known weights of different sieved sizes (125 microns-180 microns, 90 microns-125 microns, and 63 microns-90 micr… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

1
6
0

Year Published

2001
2001
2002
2002

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(7 citation statements)
references
References 49 publications
1
6
0
Order By: Relevance
“…The standard sampling technique for dry solids on hard smooth surfaces (Kim et al, 2000) did not work, because the 3-mm inlet of the "lter cassette became blocked by a wet Microtox reagent pebble. The cassette was also too large to allow 1.0 mL of reconstitution solution to dissolve all the solid on the "lter surface, but 2.0 mL did.…”
Section: Sampling Microtox Reagent Spillsmentioning
confidence: 99%
See 2 more Smart Citations
“…The standard sampling technique for dry solids on hard smooth surfaces (Kim et al, 2000) did not work, because the 3-mm inlet of the "lter cassette became blocked by a wet Microtox reagent pebble. The cassette was also too large to allow 1.0 mL of reconstitution solution to dissolve all the solid on the "lter surface, but 2.0 mL did.…”
Section: Sampling Microtox Reagent Spillsmentioning
confidence: 99%
“…The sampling probe was held with the thumb and index "nger at a 453 angle and a #ow rate of 4.0 L/min. The di!erence in mass of the probe and cassette after sampling relative to that before is the mass collected, and is compared with the mass applied to de"ne sampling e$ciency per sampling pass or over a number of sampling passes (Kim et al, 2000). One sample pass is from along the inner edge of the template area to its center in patterns of squares of progressively decreasing area.…”
Section: Surface Sampling For Microtox Reagent Spillsmentioning
confidence: 99%
See 1 more Smart Citation
“…(25) This method employed a portable, battery-operated pump in conjunction with an air sampling cassette. (24) Their results demonstrated a dust collection ef ciency of greater than 85 percent with good precision (CV < 11%) on hard surfaces. The ef ciency and precision of the collection was independent of particle size in the range of 63 to 180 ¹m and sample load in the range of from 9.3 to 169 mg dust.…”
mentioning
confidence: 97%
“…Because of this, the sampling precision tends to be very low. (24) This imprecision can lead to misclassi cation of exposure, resulting in statistically insigni cant associations with various outcomes. Kim et al recently published a dust sampling protocol for the determination of lead concentration in surface dust based on ASTM Method No.…”