Optimizing 100%‐renewable grids through shifting residential water‐heater load

Abstract: Summary A low‐carbon electricity supply for Australia was simulated, and the installed capacity of the electrical grid was optimized by shifting the electricity demand of residential electric water heaters (EWHs). The load‐shifting potential of Australia was estimated for each hour of the simulation period using a nationwide aggregate EWH load model on a 90 × 110 raster grid. The electricity demand of water heaters was shifted from periods of low renewable resource and high demand to periods of high renewable … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
11
0

Year Published

2019
2019
2022
2022

Publication Types

Select...
6
1
1

Relationship

1
7

Authors

Journals

citations
Cited by 20 publications
(11 citation statements)
references
References 34 publications
0
11
0
Order By: Relevance
“…Other kinds of flexible loads, besides those that we can identify statistically, are likely shiftable using demand-side thermal storage. Water heating might be the easiest current use of electricity that is shiftable ( Buescher et al., 2015 ; Passenberg et al., 2016 ; Ali et al., 2019 ). Although some water-heating demand may be captured by our estimates, the timing of water-heating demand tends to be more closely associated with use, not with ambient temperature, and thus less estimable in this manner.…”
Section: Discussionmentioning
confidence: 99%
“…Other kinds of flexible loads, besides those that we can identify statistically, are likely shiftable using demand-side thermal storage. Water heating might be the easiest current use of electricity that is shiftable ( Buescher et al., 2015 ; Passenberg et al., 2016 ; Ali et al., 2019 ). Although some water-heating demand may be captured by our estimates, the timing of water-heating demand tends to be more closely associated with use, not with ambient temperature, and thus less estimable in this manner.…”
Section: Discussionmentioning
confidence: 99%
“…5 For example, the Energy Information Administration reports that HVAC systems comprise 26% of use from both residential and commercial sectors while attributing 72% of total load to these sectors, implying a total HVAC share of about Other kinds of flexible loads, besides those that we can identify statistically, are likely shiftable using demand-side thermal storage. Water heating might be the easiest current use of electricity that is shiftable (22)(23)(24)(25). While some water-heating demand may be captured by our estimates, the timing of water-heating demand tends to be more closely associated with use, not with ambient temperature, and thus less estimable in this manner.…”
Section: Shiftable Demand Over Different Temporal and Geographic Scalesmentioning
confidence: 96%
“…Most studies are in hourly resolution, while only six articles describe a transition (Aboumahboub et al, 2020;Hong et al, 2014;Howard et al, 2018;Mason et al, 2010Mason et al, , 2013Turner et al, 2013), and the other 21 articles are overnight studies. Most articles are limited to the power sector, but two articles cover the power and heat sector (Ali et al, 2019;Kharel & Shabani, 2018).…”
Section: Australia and New Zealandmentioning