The electrical control activity of the large intestine was recorded in six pigs using a SQUID magnetometer. The study was performed in pre- and post-colectomy/sham-colectomy conditions. The biomagnetic field associated with colonic ECA changed drastically in subjects that underwent the colectomy procedure, whereas the signal for the control animals was nearly unchanged. Power spectral analysis was used to determine the average changes of dominant frequency and amplitude between baseline versus colectomy and sham-colectomy conditions. The dominant frequency was increased by 68 +/- 24% (versus 2 +/- 3% in control). The amplitude was decreased by 69 +/- 24% (versus 13 +/- 17% in control). This is the first study of transabdominal magnetic fields associated with colonic ECA, suggests some of the side effects generated in colectomy surgery and shows the utility of the biomagnetic technique in studies of the large intestine.