Abstract: RESUMO Atropelamentos de animais silvestres são frequentes e muitas vezes causam fraturas ósseas que, se não tratadas adequadamente, levam à morte do animal por complicações ou por inabilidade de sobrevivência no seu habitat natural. O objetivo do presente trabalho foi relatar o uso de placa associada ao pino intramedular e ao biovidro 60S (BV60S) para o tratamento de fratura de fêmur em tamanduá-bandeira. O animal foi resgatado pela polícia ambiental com suspeita de atropelamento. Foi sedado para avaliação cl… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2

Citation Types

0
2
0

Year Published

2021
2021
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(2 citation statements)
references
References 4 publications
0
2
0
Order By: Relevance
“…There are 2 others reports of femoral osteosynthesis in giant anteaters: the first one used an intramedullary pin and was unsuccessful due to mobility and osteomyelitis, leading to the euthanasia of the animal [2]. The second one, taking in account the first report, used a locking plate and an intramedullary pin [1]. Since the trochanteric osteotomy was not performed, the locking plate was placed in a more cranial position in order to avoid the crest, which is not the ideal placement.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…There are 2 others reports of femoral osteosynthesis in giant anteaters: the first one used an intramedullary pin and was unsuccessful due to mobility and osteomyelitis, leading to the euthanasia of the animal [2]. The second one, taking in account the first report, used a locking plate and an intramedullary pin [1]. Since the trochanteric osteotomy was not performed, the locking plate was placed in a more cranial position in order to avoid the crest, which is not the ideal placement.…”
Section: Discussionmentioning
confidence: 99%
“…Since the trochanteric osteotomy was not performed, the locking plate was placed in a more cranial position in order to avoid the crest, which is not the ideal placement. To account for this change, they chose to insert an intramedullary pin as well so the implants would provide a good stability [1].…”