The treatment of fractures from the thoracic limb in giant anteaters is extremely challenging. Unfamiliar and peculiar anatomical characteristics, robust musculature and the imminent need for an early return to limb function highlight such challenges. The objective of this report was to describe the successful use of anatomical osteosynthesis with a robust locking compression plate in a humeral fracture of an adult giant anteater. The patient was rescued on the highway after being run over and presented for treatment at the Veterinary Teaching Hospital. Surgical stabilization was performed using a craniomedial approach to the humerus, using a customized broad 3.5mm locking compression plate. The patient presented early limb support at 24 hours postoperatively. Radiographic monitoring was performed at 30, 60 and 90 days postoperatively, and bone healing was observed without any complications. It is concluded that the treatment of humerus fractures in giant anteaters requires robust fixation. The use of a reinforced locking compression plate system proved to be effective and adequate to the mechanical load that an adult individual of this species needs for early use of the thoracic limb and, at the same time, efficient in controlling interfragmentary movement, which allowed fracture consolidation.
A free-living, adult male maned wolf (Chrysocyon brachyurus) was referred to the Governador “Laudo Natel” – FCAV/Unesp veterinary hospital after being found with skin lesions and a fracture on the right pelvic limb, which had to be amputated due to compromised integrity. Around 20 days later, bilateral accentuated swollen on humerus-radius-ulna articulation was observed. The synovial liquid was drained and sent to the laboratory for synovial cytology with Rosenfeld staining that revealed predominantly degenerated neutrophils with karyolytic chromatin associated with intracellular inclusions suggestive of Hepatozoon sp. gametocytes. Blood and synovial liquid samples were submitted to molecular analysis, aiming to amplify the Hepatozoon spp. 18S rRNA gene fragment. Despite the positioning of the found Hepatozoon sequence together with Hepatozoon canis previously detected in domestic carnivores, the BLAST analysis showed only 98% identity with H. canis. To the best of the authors’ knowledge, this is the first time a Hepatozoon was detected in the synovial liquid by clinical pathology and molecular analyses.
Background: Locking bone plates for internal fixation are characterized by plates with a locknut by screwing in a threaded chamber. The increased stability associated with less vascular lesion contribute to the lower risk of complications and makes the locking bone plates especially interesting in fracture management of wild animals to be reintroduced into nature.The aim of this report is to describe the case of a black capuchin monkey with a femoral fracture, submitted to internal fixation using locking plate, with a satisfactory postoperative evolution, characterized by the bone consolidation and full recovery of the function of the member.Case: An exemplar of an adult male black capuchin monkey (Sapajus nigritus) with 4.2 kg of body weight was presented due to a comminuted, diaphyseal fracture of the left femur. The animal was then submitted to internal fixation of the femoral fracture using a 2.0 mm locking plate with 11 holes. For the internal fixation, the plate was contoured and positioned on the lateral surface of the bone. In addition, four locking screws were inserted through both cortices in the proximal bone segment, while other three locking screws were inserted in the distal bone segment. Two of the distal locking screws were inserted through both bone cortices, while one of them were inserted through only one bone cortical. The animal showedcomplete functional recovery of the left hind limb at 30 days postoperatively. Despite this, it was visualized at the radiographic examination a partial release of the plate from the distal bone segment. Due to this, the animal was submitted to another surgical intervention to replace the distal locking screws by bicortical locking screws. The animal showed hind limb weight support at the second day postoperatively. The complete functional recovery of the left hind limb, however, was verified at 26 days postoperatively. In this moment, it was performed a new radiographic examination, which allowed the visualization of bone consolidation, and the animal was reintroduced into its natural habitat.Discussion: The choice of the bone plate may play a fundamental role in the bone healing process. Among many bone plates configuration, locking plates are highlighted, as they offer greater angular stability to the fracture and result in less injuring periosteum and blood vessels. In addition, other methods for internal fixation are related to numerous postoperative complications. Despite the low rate of complications of the locking system, in the present case, it was visualized the partial release of the plate from the distal bone segment, which is probably related to the higher concentration of load near the sniffle joint, and the early release of one monocortical screw. The use of monocortical screws is permissible whenproperly locked in the threaded chambers of the plate. In the present case, however, it is believed that the early release of the distal monocortical screw is probably related to the incompletely screw head locked in the threaded chamber of the plate. Therefore, the use of bicortical screws should be preferred even using locking systems, especially in anatomical regions subjected to a higher concentration of load, as near the sniffle joint. In addition, it is concluded that the locking plate maybe a viable option for the treatment of long bone fractures in wild animals, in particular femoral fractures of specimens of black capuchin monkey (Sapajus nigritus).Keywords: wild animals, internal fixation, fracture.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.