2020
DOI: 10.21203/rs.3.rs-38738/v4
|View full text |Cite
Preprint
|
Sign up to set email alerts
|

Outcome of a single XEN microstent implant for glaucoma patients with different types of glaucoma

Abstract: Background The aim of this retrospective study was to compare the efficacy and safety profile of a single XEN-microstent in different types of primary and secondary open angle glaucoma.Methods A single XEN microstent was implanted in patients with primary open-angle glaucoma (POAG), normal-tension glaucoma (NTG), pseudoexfoliation glaucoma (PEX) and secondary glaucoma (Sec.Gl). The intraocular pressure (IOP), the active substances of the applied IOP-lowering drugs, the best corrected visual acuity (BCVA) and t… Show more

Help me understand this report
View published versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
4
0
3

Year Published

2021
2021
2022
2022

Publication Types

Select...
4

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(7 citation statements)
references
References 19 publications
0
4
0
3
Order By: Relevance
“…Since the type of glaucoma is discussed regarding its influence on the outcome of glaucoma surgery [17,18], its effect was included in our statistical approach. Thus, we evaluated our entire data taking both the diagnosis as well as surgery into account.…”
Section: Discussionmentioning
confidence: 99%
“…Since the type of glaucoma is discussed regarding its influence on the outcome of glaucoma surgery [17,18], its effect was included in our statistical approach. Thus, we evaluated our entire data taking both the diagnosis as well as surgery into account.…”
Section: Discussionmentioning
confidence: 99%
“…Data on the rate of postoperative needling following a primary TE or a primary XEN implantation in the literature vary. A number of studies observed needling rates of 33-45 % during the first 12 months after a primary XEN implantation [10,11,26], and 32.5-53 % after a secondary XEN implantation [23,24]. In the APEX study, a needling rate of 41.1 % (n = 83/202) was observed after 24 months; there was no statistically significant difference for this parameter between the two study populations analyzed (XEN implantation only or XEN implantation in combination with a cataract operation) [10].…”
Section: Discussionmentioning
confidence: 99%
“…Es handelt sich um ein 6 mm langes Gelatineröhrchen mit einem äußeren Durchmesser von 150 µm und einem Lumen von 45 µm, welches das Kammerwasser unter Umgehung der physiologischen Abflusswege aus der Vorderkammer unter die Bindehaut leitet, wo es über eine sich im Verlauf bildende Filtrationszone im Sinne eines Sickerkissens resorbiert wird. Somit kann eine Reduzierung des IOD sowie der nötigen applizierten Medikamente bei gutem Sicherheitsprofil erreicht werden [10,11].…”
Section: Methodsunclassified
See 1 more Smart Citation
“…123 In another study, XEN gel stent appeared to be as effective or more effective in IOP reduction as it is a bleb raising procedure (but less hypotony than trabeculectomy): the IOP for NTG group reduced from 16.6 ± 3.4 to 11.6 ± 2.2 mmHg. 124 Dataset with longer duration of follow-ups will be needed to see long term efficacy and safety of these MIGS devices.…”
Section: Updates In Treatment: Surgical Interventions Lasers and Newe...mentioning
confidence: 99%