2014
DOI: 10.1016/j.jtcvs.2014.05.063
|View full text |Cite
|
Sign up to set email alerts
|

Outcomes after implantation of partial-support left ventricular assist devices in inotropic-dependent patients: Do we still need full-support assist devices?

Abstract: Partial LVAD support may be clinically efficacious in inotropic and intra-aortic balloon pump-dependent patients. On the basis of our experience and evidence of previous research, such patients may benefit from minimally invasive access, no need for sternotomy and cardiopulmonary bypass, a short implantation time, an easy exchange if necessary, and a lower risk of subsequent heart transplantation. Because the implantation is performed without sternotomy, device upgrade is feasible with a comparatively low oper… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
7
0

Year Published

2015
2015
2022
2022

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 10 publications
(8 citation statements)
references
References 14 publications
1
7
0
Order By: Relevance
“…The LVAD has an additive contribution to the arterial system that provides a constant blood flow that complements the LV ejection output while reducing LV physical diastolic loading. In these simulations, output from the LVAD was set at 2.0 L/min and again at 4.5 L/min, indicative of the range of realistic output from the miniaturized newer-generation LVADs ( 8 , 12 ). Aside from the LVAD, all other fluid exchanges are pressure-driven by the realistic mechanical model of the 4-chamber heart.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The LVAD has an additive contribution to the arterial system that provides a constant blood flow that complements the LV ejection output while reducing LV physical diastolic loading. In these simulations, output from the LVAD was set at 2.0 L/min and again at 4.5 L/min, indicative of the range of realistic output from the miniaturized newer-generation LVADs ( 8 , 12 ). Aside from the LVAD, all other fluid exchanges are pressure-driven by the realistic mechanical model of the 4-chamber heart.…”
Section: Methodsmentioning
confidence: 99%
“…Furthermore, roughly 5% of LVAD-treated patients experience a full recovery, allowing for reduced support and, in some cases, device explantation ( 10 , 11 ). Recent results show that miniaturized, less invasive, partial-support devices operating at low flow rates may have the potential to be used in more patients, particularly those with INTERMACS classification 4 and greater ( 12 , 13 ).…”
Section: Introductionmentioning
confidence: 99%
“…This is supported by recent experiences with partial-support devices for long-term-support in elderly patients with chronic heart failure. 27,28 …”
Section: Discussionmentioning
confidence: 99%
“…newer LVAD devices, such as the Synergy Pocket micropump (HVAD, HeartWare Inc., Framingham, MA), have been used for such application. 11 Authors have used the Synergy device and have shown improved hemodynamics, end-organ perfusion, and quality of life. 10,12 The use of this partial support device has been shown to be clinically efficacious and safe in certain patient populations and is likely to be a future viable option.…”
Section: A New Implant Strategy For Bridged Patientsmentioning
confidence: 99%
“…[10][11][12] In this study, we aimed to compare early outcomes of bridge-to-transplant patients with prior sternotomy who received either conventional sternotomy or alternative outflow graft strategies.…”
mentioning