Magnetic induction tomography is an imaging
technique used to image electromagnetic properties of an object
by using the eddy current effect. (MIT) is a non-destructive
method that greatly is used in the agriculture industry. This
method provided an opportunity to improve the quality of
agricultural products. MIT simulation was used for agarwood
existence detection. This paper presented for the simulation
system contains 7 channel coils receiver and a channel transmitter
which is a sensing detector. This experiment aims to demonstrate
the reaction of induced current density and magnetic field at 10
MHz frequency. Then, it also determines the optimal solenoid coil
to be used for a better outcome for the magnetic induction system.
The simulation result shows that coil diameter, coil length, and
coil layer have a crucial role in the great performance of the
induced current and magnetic field. The more coil turns, the
greater the strength of the permanent magnetic field around the
solenoid coil. The result of the simulation is important and needs
to be considered to verify the effectiveness of the system for
developing the magnetic induction circuit design.