2004
DOI: 10.1016/j.chroma.2003.10.054
|View full text |Cite
|
Sign up to set email alerts
|

Overview of the status and applications of capillary electrophoresis to the analysis of small molecules

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
64
0
4

Year Published

2005
2005
2015
2015

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 122 publications
(68 citation statements)
references
References 96 publications
(93 reference statements)
0
64
0
4
Order By: Relevance
“…Multicapillary CE instruments have been applied primarily to DNA sequencing, which in general presents no problem with sensitivity issues because of concentration amplification provided by PCR. Some commercial multicapillary CE instruments can be adapted for high-throughput analysis of proteins and peptides, although little information has been reported in this area (40). To compensate for such low throughput, investigators have immobilized multiple capture antibodies in the forepart of the same capillary, enabling selection and capture of several different analytes per single sample introduction (37 ).…”
Section: Applicationsmentioning
confidence: 99%
“…Multicapillary CE instruments have been applied primarily to DNA sequencing, which in general presents no problem with sensitivity issues because of concentration amplification provided by PCR. Some commercial multicapillary CE instruments can be adapted for high-throughput analysis of proteins and peptides, although little information has been reported in this area (40). To compensate for such low throughput, investigators have immobilized multiple capture antibodies in the forepart of the same capillary, enabling selection and capture of several different analytes per single sample introduction (37 ).…”
Section: Applicationsmentioning
confidence: 99%
“…[4][5][6][7][8][9][10][11][12] The mass sensitivity (S m ), defined as the minimum amount of analyte detectable, of NMR can be expressed as (2) where ω 0 is the operating frequency of the NMR system, M is the number of moles of analyte within the observe volume of the NMR detector, t is the total data acquisition time, and d c is the diameter of the NMR radio frequency coil, which is usually either a solenoid or saddle geometry. Equation 2 shows that one ideally performs experiments at the highest magnetic field strength, with the maximum concentration of analyte, and the smallest diameter NMR coil.…”
mentioning
confidence: 99%
“…Em análises agroquímicas, a aplicação da eletroforese capilar tem mostrado sucesso na determinação de muitos fungicidas, herbicidas, inseticidas, acaricidas em água, solo e gêneros alimentícios. Resíduos de fármacos, tipicamente antibióticos, em alguns gêneros alimentícios de origem animal têm também sido mensurados por eletroforese capilar, como exemplo a oxitetraciclina em tecido de porco e a enrofloxacina em amostras de frango [31] . O primeiro estudo com uso de eletroforese capilar na análise de antibióticos da classe dos aminoglicosídeos utilizou detecção espectrofotométrica indireta, em pH ácido sob condições de polaridade invertida.…”
Section: Técnicas De Separação Eletroforese Capilarunclassified