Paper spray-atmospheric pressure photoionization-high resolution mass spectrometry for the direct analysis of neutral fluorinated compounds in waterproof impregnation sprays

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(3 citation statements)
references
References 32 publications
0
3
0
Order By: Relevance
“…Previous works have also illustrated that the Kr lamp generally exhibited the best capacity among various UV lamps for the photoionization of low-polarity PAHs. 35–37 The main reason is that the IE values of most PAHs are much lower than the photon energy of the emitted light of the Kr lamp while the IE values of most solvents and gases are much higher than the photon energy of the emitted light of the Kr lamp, leading to the effective and selective ionization of PAHs. For the Ar lamp, it may ionize some solvents and gases due to the high IE.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Previous works have also illustrated that the Kr lamp generally exhibited the best capacity among various UV lamps for the photoionization of low-polarity PAHs. 35–37 The main reason is that the IE values of most PAHs are much lower than the photon energy of the emitted light of the Kr lamp while the IE values of most solvents and gases are much higher than the photon energy of the emitted light of the Kr lamp, leading to the effective and selective ionization of PAHs. For the Ar lamp, it may ionize some solvents and gases due to the high IE.…”
Section: Resultsmentioning
confidence: 99%
“…For indeno[1,2,3-cd]pyrene, the results demonstrated that the signal intensity of indeno[1,2,3-cd]pyrene acquired by nano-APPI increased significantly when the voltage value increased from +1.50 to +3.00 kV. However, the [35][36][37] The main reason is that the IE values of most PAHs are much lower than the photon energy of the emitted light of the Kr lamp while the IE values of most solvents and gases are much higher than the photon energy of the emitted light of the Kr lamp, leading to the effective and selective ionization of PAHs. For the Ar lamp, it may ionize some solvents and gases due to the high IE.…”
Section: Optimization Of Nano-appimentioning
confidence: 95%
“…The application of solvent and high voltage then results in electrospray as per traditional PS‐MS, achieving sample analysis in less than 1 min, though with significantly lower sensitivity than the LC‐MS/MS method used for comparison. Finally, Foest 179 and Seró 180 et al. each respectively coupled PS‐MS with a flexible microtube plasma and atmospheric pressure photoionization to facilitate the ionization of less polar analytes, Wang et al.…”
Section: Applications Of Aimsmentioning
confidence: 99%