2012
DOI: 10.1074/mcp.o112.020131
|View full text |Cite
|
Sign up to set email alerts
|

Parallel Reaction Monitoring for High Resolution and High Mass Accuracy Quantitative, Targeted Proteomics

Abstract: Selected reaction monitoring on a triple quadrupole mass spectrometer is currently experiencing a renaissance within the proteomics community for its, as yet, unparalleled ability to characterize and quantify a set of proteins reproducibly, completely, and with high sensitivity. Given the immense benefit that high resolution and accurate mass instruments have brought to the discovery proteomics field, we wondered if highly accurate mass measurement capabilities could be leveraged to provide benefits in the tar… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

7
979
1
1

Year Published

2015
2015
2023
2023

Publication Types

Select...
6
4

Relationship

0
10

Authors

Journals

citations
Cited by 1,107 publications
(988 citation statements)
references
References 65 publications
7
979
1
1
Order By: Relevance
“…ToF-MRM assays have the inherent capability to be multiplexed and thus have incorporated into a single analysis these related analytes and their respective isotopically labelled standards for parallel quantitative measurement. High level selectivity that may be required to delineate some species in multiplex assays, those displaying extremely similar retention time/mass-to-charge profiles, is benefited by employment of the high resolution and high mass accuracy that is afforded by new generation Q-ToF or Q-Orbitrap instruments [30][31][32].…”
Section: Discussionmentioning
confidence: 99%
“…ToF-MRM assays have the inherent capability to be multiplexed and thus have incorporated into a single analysis these related analytes and their respective isotopically labelled standards for parallel quantitative measurement. High level selectivity that may be required to delineate some species in multiplex assays, those displaying extremely similar retention time/mass-to-charge profiles, is benefited by employment of the high resolution and high mass accuracy that is afforded by new generation Q-ToF or Q-Orbitrap instruments [30][31][32].…”
Section: Discussionmentioning
confidence: 99%
“…Stateof-the-art targeted methods are mainly performed in S/MRM and PRM mode on a low-resolution triple quadrupole and a high-resolution quadrupole Orbitrap mass spectrometer, respectively (Fig. 2, middle panel) (84,86). Such MS-based targeted platforms require a priori knowledge of the molecular targets.…”
Section: Identification and Quantification Of Mhc-associated Peptidesmentioning
confidence: 99%
“…Variants of MRM assays can also exist for ion trap instruments (pseudo-selected reaction monitoring, pSRM) or quadrupole-Orbitrap hybrid instruments (parallel reaction monitoring, PRM). PRM is a targeted proteomics strategy where all products of a precursor peptide are simultaneously monitored under conditions that offer high resolution and ff ff high mass accuracy [155]. Preliminary reports suggest that PRM analyses exhibit dynamic range and performance characteristics that rival those of MRM analyses performed on triple quadrupole instruments [155,156].…”
Section: Mass Spectrometry (Ms) Methodsmentioning
confidence: 99%