2018
DOI: 10.1021/acs.analchem.7b05387
|View full text |Cite
|
Sign up to set email alerts
|

Parameter Optimization for Feature and Hit Generation in a General Unknown Screening Method—Proof of Concept Study Using a Design of Experiment Approach for a High Resolution Mass Spectrometry Procedure after Data Independent Acquisition

Abstract: High resolution mass spectrometry and modern data independent acquisition (DIA) methods enable the creation of general unknown screening (GUS) procedures. However, even when DIA is used, its potential is far from being exploited, because often, the untargeted acquisition is followed by a targeted search. Applying an actual GUS (including untargeted screening) produces an immense amount of data that must be dealt with. An optimization of the parameters regulating the feature detection and hit generation algorit… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2019
2019
2020
2020

Publication Types

Select...
5

Relationship

2
3

Authors

Journals

citations
Cited by 10 publications
(11 citation statements)
references
References 20 publications
0
11
0
Order By: Relevance
“…However, when using a slower model Orbitrap mass analyzer, the methods may only generate 3–5 points across narrow chromatographic peaks that can make it difficult to even determine whether an analyte is present. Several publications have demonstrated the equivalent capabilities using Orbitrap high‐resolution mass spectrometers for quantitation compared with traditional triple quadrupole methods . The number of data points across an elution peak will be important if more rigorous quantitation is required.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…However, when using a slower model Orbitrap mass analyzer, the methods may only generate 3–5 points across narrow chromatographic peaks that can make it difficult to even determine whether an analyte is present. Several publications have demonstrated the equivalent capabilities using Orbitrap high‐resolution mass spectrometers for quantitation compared with traditional triple quadrupole methods . The number of data points across an elution peak will be important if more rigorous quantitation is required.…”
Section: Resultsmentioning
confidence: 99%
“…Data acquisition methods were initially evaluated by determining how well targeted compounds could be detected and identified in eel samples fortified with a mix of analytes (Table ). Collecting data using non‐targeted acquisition (AIF or DIA) and then analyzing the results against a list of targeted analytes is a common strategy for HRMS methods and can be referred to as “non‐targeted data acquisition targeted analyses or “nDATA.” In order for a method to be applicable to regulatory monitoring, it was important to determine that critical analytes, including those listed in the current compliance program, could be identified in eel at the established target testing levels.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…Still, unknown peaks remain with untargeted acquisition which must be laboriously identified using in silico and literature data. Attempts are being made to tackle the big data problem of untargeted acquisition by optimizing software parameters but still, targeted acquisition with its high specificity and sensitivity remains a routine friendly and valid option.…”
Section: Introductionmentioning
confidence: 99%
“…Using statistical software such as ProGenesis QI enables it to cope with the huge amount of data. Recently, optimization of software parameters using a Design of Experiment (DoE) approach has been proposed in a proof of concept study to reduce the amount of data …”
Section: Introductionmentioning
confidence: 99%