2001
DOI: 10.1351/pac200173060969
|View full text |Cite
|
Sign up to set email alerts
|

Part B. Retention parameters in gas chromatograpy

Abstract: Republication or reproduction of this report or its storage and/or dissemination by electronic means is permitted without the need for formal IUPAC permission on condition that an acknowledgment, with full reference to the source along with use of the copyright symbol ©, the name IUPAC, and the year of publication, are prominently visible. Publication of a translation into another language is subject to the additional condition of prior approval from the relevant IUPAC National Adhering Organization. CONTENTS … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
13
0

Year Published

2004
2004
2019
2019

Publication Types

Select...
5
5

Relationship

0
10

Authors

Journals

citations
Cited by 69 publications
(13 citation statements)
references
References 23 publications
(39 reference statements)
0
13
0
Order By: Relevance
“…When the nature of the organic substances to be separated is known, one may find a suitable solvent system by searching the literature for solvent systems that have been successfully applied to similar compounds [2][3][4][5][6][7][8][9][10]. In case of organic-aqueous two-phase systems, the organic phase consists of one solvent or of a mixture of different solvents.…”
Section: Two Immiscible Phasesmentioning
confidence: 99%
“…When the nature of the organic substances to be separated is known, one may find a suitable solvent system by searching the literature for solvent systems that have been successfully applied to similar compounds [2][3][4][5][6][7][8][9][10]. In case of organic-aqueous two-phase systems, the organic phase consists of one solvent or of a mixture of different solvents.…”
Section: Two Immiscible Phasesmentioning
confidence: 99%
“…The use of silica as the backbone material for stationary phase in high-performance liquid chromatography (HPLC) limits the mobile-phase pH to the 2-8 range. Acidic mobile phases could cleave the organic bonded moiety; basic ones could dissolve the silica, although modern and expensive HPLC stationary phases can work with pH 1 and/or pH 10 mobile phases [10]. In contrast, if the solvents used to make the biphasic liquid system are not sensitive to pH, there are no additional pH problems as the material most frequently used in CCC columns is Teflon.…”
Section: Unique Possibilitiesmentioning
confidence: 99%
“…The retention factor of reference compounds were obtained according to the IUPAC approach [17], based on the extracolumn time, t ext , correction:…”
Section: Bmc Measurementsmentioning
confidence: 99%