Partial discharge analysis for predictive maintenance of generator of geothermal power plant

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
2
0
2

Year Published

2016
2016
2023
2023

Publication Types

Select...
3
2
1

Relationship

0
6

Authors

Journals

citations
Cited by 6 publications
(4 citation statements)
references
References 1 publication
0
2
0
2
Order By: Relevance
“…Data must not only be recorded but also processed and analyzed (Cachada et al 2018). Appropriate tools not only process sensor data but also take the maintenance history, operational data, design and application into account (Darwanto et al 2012).…”
Section: Predictive Maintenance and The Related Literaturementioning
confidence: 99%
See 1 more Smart Citation
“…Data must not only be recorded but also processed and analyzed (Cachada et al 2018). Appropriate tools not only process sensor data but also take the maintenance history, operational data, design and application into account (Darwanto et al 2012).…”
Section: Predictive Maintenance and The Related Literaturementioning
confidence: 99%
“…Maintenance activities are only performed when required as long as the system is still running in its intended way (Mattes et al 2012). PdM reduces the probability of extensive failures (Darwanto et al 2012). From an economic perspective, costs are reduced because the maintenance activities are less precise, and there is less likelihood of default (Wang et al 2009).…”
Section: Predictive Maintenance and The Related Literaturementioning
confidence: 99%
“…Desde el punto de vista de estimación del estado de los equipos de alta tensión, el registro de las descargas parciales es la herramienta de diagnóstico más reconocida en la literatura especializada (Medrano, 2013;Tavner, et al, 2008;Stone, 2005) y es la variable que representa más de dos terceras partes del índice de daño cualitativo ligado a defectos individuales en el devanado del estator (Kartalovic, et al 2014). Dorrbercker, Darwanto y Torres documentan sus experiencias con el diagnóstico del aislamiento de generadores de potencia mediante esta variable (Dorrbercker, et al, 2012;Darwanto, et al, 2012;Torres, et al, 2010).…”
Section: Introductionunclassified
“…Las normas internacionales han ido regularizando los métodos de prueba. Sin embargo, son las experiencias publicadas, acerca de la evaluación de los sistemas aislantes, las que han ido enriqueciendo la capacidad de detección de los mecanismos de deterioro en forma incipiente (Dorrbercker, et al, 2012;Darwanto, et al, 2012;Torres, et al, 2010).…”
Section: Introductionunclassified