2018
DOI: 10.1016/j.nima.2018.06.084
|View full text |Cite
|
Sign up to set email alerts
|

Particle identification studies with a full-size 4-GEM prototype for the ALICE TPC upgrade

Abstract: A large Time Projection Chamber is the main device for tracking and charged-particle identification in the ALICE experiment at the CERN LHC. After the second long shutdown in 2019/20, the LHC will deliver Pb beams colliding at an interaction rate of about 50 kHz, which is about a factor of 50 above the present readout rate of the TPC. This will result in a significant improvement on the sensitivity to rare probes that are considered key observables to characterize the QCD matter created in such collisions. In … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
7
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
6
2
1

Relationship

1
8

Authors

Journals

citations
Cited by 13 publications
(7 citation statements)
references
References 19 publications
0
7
0
Order By: Relevance
“…The new chambers will employ stacks containing Standard (S, 140 µm pitch) and Large Pitch (LP, 280 µm pitch) GEMs in the configuration S-LP-LP-S. This solution fulfils challenging requirements of the upgrade in terms of energy resolution, ion backflow (IBF) and stability against electrical discharges [5,6].…”
Section: Introductionmentioning
confidence: 99%
“…The new chambers will employ stacks containing Standard (S, 140 µm pitch) and Large Pitch (LP, 280 µm pitch) GEMs in the configuration S-LP-LP-S. This solution fulfils challenging requirements of the upgrade in terms of energy resolution, ion backflow (IBF) and stability against electrical discharges [5,6].…”
Section: Introductionmentioning
confidence: 99%
“…In order to validate the performance of a large-size detector equipped with a stack of four GEMs in terms of d𝐸/d𝑥 resolution, a prototype IROC was tested at the CERN Proton Synchrotron [7,36]. The main result of this campaign is shown in Fig.…”
Section: Particle Identification Performancementioning
confidence: 99%
“…Horizontal error bars correspond to the uncertainty of 𝜎( 55 Fe) measurement with small prototypes. Data points and simulation are taken from [36].…”
Section: Particle Identification Performancementioning
confidence: 99%
“…The fraction of ions reaching the cathode depends on the detector architecture. In recent years, MPGD schemes with enhanced ion blocking capability have been developed [4,[14][15][16][17][18][19][20][21].…”
Section: Introductionmentioning
confidence: 99%