2002
DOI: 10.1039/b203307k
|View full text |Cite
|
Sign up to set email alerts
|

Passive sampling in combination with thermal desorption and gas chromatography as a tool for self-assessment of chemical exposure

Abstract: Diffusive samplers for monitoring of air quality are user-friendly devices that can normally be operated by the user himself. Hence these samplers are suitable for self-assessment. Practical and work organisational aspects of self-assessment of chemical exposure were studied in different occupational settings. It was found that the diffusive sampler used in these studies, the Perkin-Elmer tube in combination with thermal desorption, worked well for the purpose and could be correctly handled by the individuals … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2006
2006
2016
2016

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 20 publications
(34 reference statements)
0
4
0
Order By: Relevance
“…After sampling, the collected pollutant is desorbed from the sampling media by thermal or chemical means and analyzed quantitatively. The average concentration of the pollutant in the atmosphere to which the sampler was exposed is calculated by dividing the mass of pollutant, measured analytically, by the product of the diffusion rate and sampling time …”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…After sampling, the collected pollutant is desorbed from the sampling media by thermal or chemical means and analyzed quantitatively. The average concentration of the pollutant in the atmosphere to which the sampler was exposed is calculated by dividing the mass of pollutant, measured analytically, by the product of the diffusion rate and sampling time …”
Section: Introductionmentioning
confidence: 99%
“…The average concentration of the pollutant in the atmosphere to which the sampler was exposed is calculated by dividing the mass of pollutant, measured analytically, by the product of the diffusion rate and sampling time. 1 The Ogawa NO 2 and NO X sampler have been validated using chemiluminescence measurements in ambient environments. 2,3 The Radiello sampler, developed over a decade ago for assessment of benzene exposure, 4 has been evaluated for collection of VOC using Carbograph 4 and other adsorbents.…”
Section: Introductionmentioning
confidence: 99%
“…Quantitative self-assessment is a relatively recent development and is the term used to describe an exposure assessment method where the worker performs at least the sampling himself. Research groups that have applied quantitative self-assessment approaches are not numerous (Loomis et al, 1994;Saarinen et al, 1998;Rappaport et al, 1999;Tielemans et al, 1999;Liljelind et al, 2000Liljelind et al, , 2001Egeghy et al, 2002;Sunesson et al, 2002). Results so far have been promising and suggest that it is feasible for workers to conduct exposure measurements themselves.…”
Section: Discussionmentioning
confidence: 99%
“…Diffusive samplers, also known as passive samplers, were first developed for monitoring air in the workplace and still are very used for this purpose, 1,2 but display a great potential for monitoring ambient air quality. [3][4][5][6] Continuous monitoring of VOC (volatile organic compounds) today is still only feasible for a few compounds, particularly BTEX.…”
Section: Introductionmentioning
confidence: 99%