2012
DOI: 10.1016/j.jpedsurg.2011.11.054
|View full text |Cite
|
Sign up to set email alerts
|

Patch repair for congenital diaphragmatic hernia: is it really a problem?

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
75
0
1

Year Published

2013
2013
2022
2022

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 87 publications
(77 citation statements)
references
References 20 publications
1
75
0
1
Order By: Relevance
“…24 Experience from "high-volume" CDH programs in Philadelphia, USA, and Liverpool, UK, has been strikingly different with recent studies from these centres showing very low rates of patch failure ( o 10%) using GORE-TEX. 18,25 We (like others) strongly believe that patch failure reflects a technical problem with its implantation at the primary CDH operation by the surgeon. 18,25 Minimally invasive techniques (MIS) have become available for diaphragm repair.…”
Section: Stabilisationmentioning
confidence: 90%
See 2 more Smart Citations
“…24 Experience from "high-volume" CDH programs in Philadelphia, USA, and Liverpool, UK, has been strikingly different with recent studies from these centres showing very low rates of patch failure ( o 10%) using GORE-TEX. 18,25 We (like others) strongly believe that patch failure reflects a technical problem with its implantation at the primary CDH operation by the surgeon. 18,25 Minimally invasive techniques (MIS) have become available for diaphragm repair.…”
Section: Stabilisationmentioning
confidence: 90%
“…18,25 We (like others) strongly believe that patch failure reflects a technical problem with its implantation at the primary CDH operation by the surgeon. 18,25 Minimally invasive techniques (MIS) have become available for diaphragm repair. Benefits potentially include reduced postoperative pain and improved cosmesis whilst physiological derangement(s) during operation may be hazardous in fragile newborns.…”
Section: Stabilisationmentioning
confidence: 90%
See 1 more Smart Citation
“…Fauza 57 , em artigo de revisão, comenta a retirada das mesmas células de humanos e a implantação em uma matriz acelular construindo um "músculo diafragma" a partir das próprias células do paciente. Evidentemente, isso não é uma prática corriqueira, uma vez que o Food and Drug Administration (FDA) ainda não permite sua utilização, mas é possível construir um tendão muscular diafragmá-tico autólogo, sem a necessidade de colocar uma prótese nas situações graves quando não existe diafragma 57 , visto que o uso de próteses pode levar a uma taxa de recidiva da hérnia de até 50% 58 .…”
Section: Perspectivasunclassified
“…Patch materials commonly applied include polytetrafluoroethylene (PTFE) 1 and small intestinal submucosa (SIS), derived from decellularised porcine submucosa. 2 Both types of materials have been found successful in some studies, [3][4][5] but showed high recurrence rates in others. 2,6,7 A recent meta-analysis reported no differences between PTFE and SIS, both materials having a recurrence rate of over 30%.…”
Section: Introductionmentioning
confidence: 99%