2017
DOI: 10.1088/1742-6596/777/1/012017
|View full text |Cite
|
Sign up to set email alerts
|

Patient specific quality control for Stereotactic Ablative Body Radiotherapy (SABR): it takes more than one phantom

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
2

Citation Types

0
5
0
1

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 17 publications
0
5
0
1
Order By: Relevance
“… Abbreviations: AM, additive manufacturing; DMD, digital micromirror device; FDM, Fused Deposition Modelling; LENS, laser engineering net shape; LOM, laminated object material; PJT, polymer jetting technology; SLA, stereolithography; SLS, selective laser sintering; 3D, three-dimensional printing. a The heterogeneity found in the human body is becoming more important as more sophisticated radiotherapy techniques are employed such as stereotactic radiotherapy. 89 Therefore, simulating patient-specific tissue contrast requires the utilization of available standard AM printing parameters and AM polymers to manufacture clinically usefull imaging and dosimetry phantoms. …”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“… Abbreviations: AM, additive manufacturing; DMD, digital micromirror device; FDM, Fused Deposition Modelling; LENS, laser engineering net shape; LOM, laminated object material; PJT, polymer jetting technology; SLA, stereolithography; SLS, selective laser sintering; 3D, three-dimensional printing. a The heterogeneity found in the human body is becoming more important as more sophisticated radiotherapy techniques are employed such as stereotactic radiotherapy. 89 Therefore, simulating patient-specific tissue contrast requires the utilization of available standard AM printing parameters and AM polymers to manufacture clinically usefull imaging and dosimetry phantoms. …”
Section: Discussionmentioning
confidence: 99%
“… a The heterogeneity found in the human body is becoming more important as more sophisticated radiotherapy techniques are employed such as stereotactic radiotherapy. 89 Therefore, simulating patient-specific tissue contrast requires the utilization of available standard AM printing parameters and AM polymers to manufacture clinically usefull imaging and dosimetry phantoms. …”
Section: Discussionmentioning
confidence: 99%
“…PSQA has proved challenging for stereotactic spine cases, even more so for those with surgical implants 12 . Surgical implants complicate the dosimetry further due to the presence of high‐density materials such as titanium 9 .…”
Section: Introductionmentioning
confidence: 99%
“…PSQA has proved challenging for stereotactic spine cases, even more so for those with surgical implants. 12 Surgical implants complicate the dosimetry further due to the presence of high-density materials such as titanium. 9 More recently carbon fiber-based implants have become available with the aim of improving radiotherapy treatment accuracy.…”
Section: Introductionmentioning
confidence: 99%
“…En dicha técnica se administran dosis altas por fracción a lesiones pequeñas que, sumados al movimiento de la lesión y la heterogeneidad del medio, hacen que se requiera de una radioterapia moderna y avanzada, como en el caso de: la radioterapia de intensidad modulada (IMRT), la arcoterapia volumétrica de intensidad modulada (VMAT) y la radioterapia de imagen guiada (IGRT) (Teoh et al, 2011). Teniendo en cuenta lo anterior, es de esperar que el control de calidad de paciente específico (PSQA por sus siglas en inglés) sea riguroso y se considere esencial para garantizar la entrega del tratamiento (Kron et al, 2017).…”
Section: Introductionunclassified