2017
DOI: 10.1039/c6ra27383a
|View full text |Cite
|
Sign up to set email alerts
|

Pb electrodeposition from PbO in the urea/1-ethyl-3-methylimidazolium chloride at room temperature

Abstract: In this study, we dissolved PbO in a new electrolyte urea/1-ethyl-3-methylimidazolium chloride (EMIC) and electrochemically extracted Pb.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
8
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
6
1

Relationship

1
6

Authors

Journals

citations
Cited by 19 publications
(8 citation statements)
references
References 37 publications
0
8
0
Order By: Relevance
“…It can be seen that the experimental curves for electrodeposition of metallic Pb on Gr/SiC show the best agreement with the dependence computed in the frame of the instantaneous nucleation mechanism, which is consistent with Pb electrodeposition mechanisms reported for copper, 52 silicon surface 51 and tungsten foil. 53 Further data analysis in the frame of eqn (2) and (3) showed an exponential increase of the number of active nucleation sites (N 0 ) on Gr/SiC (Fig. 8d), which is typical for an instantaneous nucleation mechanism.…”
Section: Electrodeposition Of Lead: Chronopotentiometric Stripping Anmentioning
confidence: 77%
“…It can be seen that the experimental curves for electrodeposition of metallic Pb on Gr/SiC show the best agreement with the dependence computed in the frame of the instantaneous nucleation mechanism, which is consistent with Pb electrodeposition mechanisms reported for copper, 52 silicon surface 51 and tungsten foil. 53 Further data analysis in the frame of eqn (2) and (3) showed an exponential increase of the number of active nucleation sites (N 0 ) on Gr/SiC (Fig. 8d), which is typical for an instantaneous nucleation mechanism.…”
Section: Electrodeposition Of Lead: Chronopotentiometric Stripping Anmentioning
confidence: 77%
“…Urea, Cu 2 O, and Tungsten substrate were purchased and used according to the procedure earlier described. 30 Also, urea and [EMIM]F were mixed in a molar ratio of 2:1 and then were used to dissolve 1.30 mmol Cu 2 O. This final mixture was labeled as…”
Section: Methodsmentioning
confidence: 99%
“…Cu extraction and electrochemical investigation in this system were carried out according to the procedure reported in previous literature. 30 A tungsten wire (0.05 cm in diameter) was used as the working electrode (WE), a platinum wire (0.05 cm in diameter) and silver wire (0.05 cm in diameter) were used as the counter electrode (CE) and the quasi-reference electrode (QRE), respectively. 30 All the electrodes were sanded with sandpaper, ultrasonically degreased in an ethanol solution, and then washed with deionized water before use.…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations