PCR Detection of Listeria monocytogenes in different Food Products compared with the mini-VIDAS LMO System and the Standard Procedure ISO 11290-1

Abstract: The presence of Listeria monocytogenes in 225 natural samples, including different food types, was investigated by three methods: (i) culture-based standard procedure ISO 11290-1, (ii) mini-VIDAS (Vitek Immuno Diagnostic Assay System) LMO, an enzyme linked fluorescent assay (ELFA) commercially available, and (iii) PCR using a previously established procedure. Identification of isolates recovered from the standard method and mini-VIDAS, on Oxford and PALCAM selective plates, was carried out using the API-Lis sy… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
5
0

Year Published

2011
2011
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(6 citation statements)
references
References 26 publications
1
5
0
Order By: Relevance
“…However, mini-VIDAS was less sensitive and also had lower PPV and NPV scores. This is in accordance with the results of an earlier work (Aznar & Solís, 2006) in which the PCR procedure described by Aznar and Alarcón (2003) proved more sensitive in L. monocytogenes detection than the mini-VIDAS, in a variety of naturally contaminated samples. Overall, the results obtained in this study for L. monocytogenes and E. coli O157:H7, using a high number of naturally contaminated food products, highlighted that qPCR without enrichment is a better predictive tool than mini-VIDAS, which corroborates the results obtained for Salmonella spp.…”
Section: Discussionsupporting
confidence: 93%
“…However, mini-VIDAS was less sensitive and also had lower PPV and NPV scores. This is in accordance with the results of an earlier work (Aznar & Solís, 2006) in which the PCR procedure described by Aznar and Alarcón (2003) proved more sensitive in L. monocytogenes detection than the mini-VIDAS, in a variety of naturally contaminated samples. Overall, the results obtained in this study for L. monocytogenes and E. coli O157:H7, using a high number of naturally contaminated food products, highlighted that qPCR without enrichment is a better predictive tool than mini-VIDAS, which corroborates the results obtained for Salmonella spp.…”
Section: Discussionsupporting
confidence: 93%
“…The comparison of the two sample evaluation methods revealed that RT-PCR is 2.71 to 9.40 times more sensitive than the culture method ( Table 3). The higher sensitivity of PCR methods has been reported (4,9,30,44,45), including for raw milk samples in Italy (1,5,19,20). The fact that the RT-PCR method detects dead cells should be taken into account in comparing the sensitivity of the two methods, but this difference has no impact on the development of a risk assessment of consumption of raw milk sold in vending machines.…”
Section: Discussionmentioning
confidence: 99%
“…This retrospective study confirms the well-reported higher sensitivity of the RT-PCR versus cultural method (Karns et al ., 2005 ; Chapman et al ., 2001 ; Yang et al ., 2003 ; Aznar and Solis, 2006 ; Wegmüller et al ., 1993 ); in fact, our results show that, in spite of the use of the same enrichment broth, the RT-PCR method disclosed a percentage of positive samples that were negative to cultural examination ranging between 20 and 43%, with a PCR/culture ratio between 2.37 to 5.00.…”
Section: Discussionmentioning
confidence: 99%