Pemanfaatan Sensor Mikro DHT11-Arduino untuk Monitoring Suhu dan Kelembaban Udara

Abstract: Climatic factors are an abiotic component that determines ecosystem characteristics. Rapid development activities require capable observation instruments and able to provide a variety of weather data to analyze their impact on the environment. This study aims to develop an instrument for measuring temperature and humidity as an essential component of climatic factors based on the DHT11-Arduino microsensor. Tests carried out at 30 scattered points in Cikarang Raya, Bekasi Regency, West Java. Data from the DHT11… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0
2

Year Published

2020
2020
2023
2023

Publication Types

Select...
6

Relationship

2
4

Authors

Journals

citations
Cited by 7 publications
(6 citation statements)
references
References 12 publications
0
4
0
2
Order By: Relevance
“…Data validity testing shows that the information from the Landsat series with other satellite data was declared feasible. This result shows the highest correlation in TSS, even though the correlation value for these variables is significant with p-value ≤ 0.05 (see Table 4) and its suitable for further analysis (Nudian et al, 2019). Meanwhile, when we referring to data from in-situ measurements for TSS, SST, and salinity also show information from multi-spectral satellite imagery was valid.…”
Section: Impact Of Coal-fired Power Plant On Water Qualitymentioning
confidence: 70%
“…Data validity testing shows that the information from the Landsat series with other satellite data was declared feasible. This result shows the highest correlation in TSS, even though the correlation value for these variables is significant with p-value ≤ 0.05 (see Table 4) and its suitable for further analysis (Nudian et al, 2019). Meanwhile, when we referring to data from in-situ measurements for TSS, SST, and salinity also show information from multi-spectral satellite imagery was valid.…”
Section: Impact Of Coal-fired Power Plant On Water Qualitymentioning
confidence: 70%
“…The difference between both methods, the IoT monitoring device always shows a higher value than Wunderland.com. Moreover, these differences are still within the range of DHT sensor measurement accuracy (+2 o C) [22,23]. 11.…”
Section: Placement Of Sensors In Pondsmentioning
confidence: 87%
“…Internet of Things (IoT) merupakan sebuah sistem yang memungkinkan benda-benda fisik dapat berkomunikasi satu sama lain dengan bertukar data melalui jaringan internet [8] [14] [7]. Berdasarkan hasil pengujian yang dilakukan oleh [15], di dapatkan hasil bahwa sensor DHT11 memiliki eror yang relatif kecil yaitu berkisar antara 1%-3,9%.…”
Section: Pendahuluanunclassified