Performance analysis of system heat pump - heat recuperator used for air treatment in process industry

Abstract: A detailed parametric analysis and performance optimization of the system heat pump -heat recuperator is given in this paper. Mathematical model used for analysis is formed according to the physical model of the system and practical experience. Different types of compressors, and various temperature ranges are treated. Special attention is paid to influence of condensing and evaporating temperatures on system performances, so as to different features of heat recuperator. It is found out that in accordance to t… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
2
1

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(2 citation statements)
references
References 6 publications
0
2
0
Order By: Relevance
“…In this manner, heat from the exhaust air stream is transferred through the separating plates, and into the supply air stream. Manufacturers claim gross efficiencies of up to 80% depending upon the specification of the unit (Milovančevič and Kosi 2016;Albers 2016). Many users report installation problems: BOX 1.8 Opinion evidence Some of the important disadvantages of the installed recuperator are noise and dry air.…”
Section: Box 17 Study Evidencementioning
confidence: 99%
“…In this manner, heat from the exhaust air stream is transferred through the separating plates, and into the supply air stream. Manufacturers claim gross efficiencies of up to 80% depending upon the specification of the unit (Milovančevič and Kosi 2016;Albers 2016). Many users report installation problems: BOX 1.8 Opinion evidence Some of the important disadvantages of the installed recuperator are noise and dry air.…”
Section: Box 17 Study Evidencementioning
confidence: 99%
“…In China, a large amount of geothermal energy lower than 50 ℃ in the form of low-grade energy cannot be used for residents heating due to difficulties of transforming the energy into useful high-grade energy. Heat pump is an efficient way to upgrade low temperature geothermal water up to a more feasible high temperature for residents heating and reduce the fossil energy consumption and CO 2 emission [5][6][7]. Compared to conventional vapour compression heat pumps, the CAHP cycle provides a number of attractive advantages [8,9].…”
Section: Introductionmentioning
confidence: 99%