Performance Evaluation and Optimization of A Refrigerant Distributor for Air Conditioner

Abstract: Refrigerant mal-distribution in a distributor located at the inlet of a heat exchanger used for an air conditioning system plays an important role in the heat exchanger performance. Distribution performance in the distributor is greatly affected by the flow conditions as well as the geometrical parameters of the distributor. To clarify the distribution characteristics, it is essential to know flow rates of both liquid and vapor states at every branch tube after distribution. This paper proposes a relatively si… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
4
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
6

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…Based on practical experience and the values reported by Bach et al (2012a) and Yoshioka et al (2008), it is assumed that no stronger maldistribution will occur in a reasonably designed and maintained heat pump unit. Worse effects may occur during long-term operation, e.g.…”
Section: Costs Of Maldistributionmentioning
confidence: 99%
See 1 more Smart Citation
“…Based on practical experience and the values reported by Bach et al (2012a) and Yoshioka et al (2008), it is assumed that no stronger maldistribution will occur in a reasonably designed and maintained heat pump unit. Worse effects may occur during long-term operation, e.g.…”
Section: Costs Of Maldistributionmentioning
confidence: 99%
“…A quantitative study of gas/liquid phase non-uniformity in a distributor was performed by Yoshioka et al (2008). A maximum deviation of 30% between distributor inlet quality and quality at a single distributor outlet was observed at an installation angle of 10 relative to vertical.…”
Section: Introductionmentioning
confidence: 99%
“…Based on previously reported values (Bach et al, 2012;Yoshioka et al, 2008) i n t e r n a t i o n a l j o u r n a l o f r e f r i g e r a t i o n 5 0 ( 2 0 1 5 ) 2 1 7 e2 2 6 assumed that the considered maldistribution cases represent somewhat realistic scenarios. However, both hot water production and frost and defrost is neglected in this study.…”
Section: Discussionmentioning
confidence: 99%
“…Some other scholars proposed another method to optimize the performance of refrigerant distribution by ensuring the inlet quality or the flow rate at the branch tube of the dsitributor are stable [14,16]. The research from Yoshioka et al [16] evident that the distribution for the refrigerant is significantly influenced by the change of the refrigerant flow coditions. Hence, an optimization on the geometrical parameters of the distributor was proposed to ensure the distribution remains stable over the various operating range.…”
Section: Introductionmentioning
confidence: 99%