Performance evaluation of a rapid‐scanning quadrupole mass spectrometer in the comprehensive two‐dimensional gas chromatography analysis of pesticides in water

Abstract: The performance of a novel rapid-scanning (20,000 amu/s) quadrupole mass spectrometer (qMS) has been evaluated in the comprehensive 2-D gas chromatography (GC×GC) analysis of pesticides contained in water. Analyte extraction was performed by using direct solid-phase microextraction (SPME). The MS system was operated using a rather wide m/z 50-450 mass range and a 33 Hz spectral production rate, a frequency which was found sufficient for reliable quantification. The qMS performance was evaluated considering: (i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
11
0

Year Published

2014
2014
2020
2020

Publication Types

Select...
4
2

Relationship

3
3

Authors

Journals

citations
Cited by 36 publications
(11 citation statements)
references
References 17 publications
0
11
0
Order By: Relevance
“…TIC SPME-GC×GC-qMS chromatogram of a pesticide mixture in drinking water at the 10-ppb level. For peak identification refer to [27]. (Reproduced with permission from Wiley).…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…TIC SPME-GC×GC-qMS chromatogram of a pesticide mixture in drinking water at the 10-ppb level. For peak identification refer to [27]. (Reproduced with permission from Wiley).…”
Section: Discussionmentioning
confidence: 99%
“…Purcaro et al exploited the enrichment capability of SPME coupled to GC×GC combined with a rapid-scanning qMS instrument for the determination of pesticides in drinking water [27]. A 100-μm PDMS fiber was directly immersed in drinking water to extract pesticides.…”
Section: Targeted Spme Analysismentioning
confidence: 99%
“…GC × GC was first reported in 1991 by Liu and Phillips . This now well‐known multidimensional technology is commonly performed by using a conventional column (i.e., 30 m × 0.25 mm id × 0.25 μm d f ) as first dimension ( 1 D), and a short micro‐bore column segment (i.e., 1–2 m × 0.1 mm id × 0.1 μm d f ) as second dimension ( 2 D) . The analysis timeframes are about the same as those observed in 1D GC applications (1–2 h), even though variations do exist.…”
Section: Introductionmentioning
confidence: 94%
“…GC × GC was first reported in 1991 by Liu and Phillips [1]. This now well-known multidimensional technology is commonly performed by using a conventional column (i.e., 30 m × 0.25 mm id × 0.25 μm d f ) as first dimension ( 1 D), and a short micro-bore column segment (i.e., 1-2 m × 0.1 mm id × 0.1 μm d f ) as second dimension ( 2 D) [2][3][4]. The analysis timeframes are about the same as those observed in 1D GC applications (1-2 h), even though variations Abbreviations: 1 D, first dimension; 2 D, second dimension; CM, cryogenic modulation; LRI, linear retention index; QMS, quadrupole mass spectrometry; SCCS, Scientific Committee on Consumer Safety Conflict of interest: The authors declare no financial/commercial conflict of interest.…”
Section: Introductionmentioning
confidence: 99%
“…Even though to a much lower extent, compared to LR‐TOF‐MS, rapid scanning qMS instruments have been used for targeted GC×GC applications on pesticide contaminants. For example, Purcaro et al evaluated the analytical performance of a powerful qMS system (scan speed: 20 000 amu/s) for the determination of pesticides in drinking water . High sensitivity is required in such applications because European regulations limit the presence of pesticides in drinking water at an MRL of 0.1 μg/L.…”
Section: Targeted Analysesmentioning
confidence: 99%