2014
DOI: 10.1109/tste.2014.2347967
|View full text |Cite
|
Sign up to set email alerts
|

Performance Evaluation of Three-Phase Grid-Connected Photovoltaic Inverters Using Electrolytic or Polypropylene Film Capacitors

Abstract: In grid-connected photovoltaic (PV) power stations, improving the life expectancy and long-term reliability of threephase PV inverters is urgently needed to match the significantly higher lifetime of the PV modules. A key contribution toward such improvement is replacing the conventional electrolytic film capacitors by metallized polypropylene film ones. This paper presents a detailed evaluation of a conventional three-phase grid-connected PV inverter performance when replacing the electrolytic capacitor with … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0
2

Year Published

2015
2015
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 66 publications
(30 citation statements)
references
References 25 publications
0
28
0
2
Order By: Relevance
“…The gains of G ILf are shown in Table 3. A reduced DC-link capacitance leads to the fast dynamics of the V DC control loop at the expense of an increase of the THDi of I G [16,17]. In Reference [16] a notch filter in the DC-link voltage control loop was implemented to reduce the low-frequency harmonics of I G .…”
Section: Synchronization With the Gridmentioning
confidence: 99%
See 3 more Smart Citations
“…The gains of G ILf are shown in Table 3. A reduced DC-link capacitance leads to the fast dynamics of the V DC control loop at the expense of an increase of the THDi of I G [16,17]. In Reference [16] a notch filter in the DC-link voltage control loop was implemented to reduce the low-frequency harmonics of I G .…”
Section: Synchronization With the Gridmentioning
confidence: 99%
“…The estimation of P G , P G_est , depends on I G and on the grid voltage RMS value (V G ) so that variations of V G perturb the calculations of P G_est . To overcome this issue, the value of the signal v' pk is used to calculate the estimation of P G as it is shown in Equation (17). The signal v' pk is the amplitude of the fundamental of V G and is provided by the FLL-SOGI, not requiring additional computational resources.…”
Section: Estimation Of the Power Injected Into The Grid In The Sensormentioning
confidence: 99%
See 2 more Smart Citations
“…Some devices include a decoupling circuit or ripple port circuit to absorb the reactive power [10,11]; however, this increases fabrication costs and results in switching losses that reduce the efficiency of the MI. As shown in Figure 1a [12][13][14], a film capacitor with a longer lifespan can be used as a substitute for an E-cap in typical single-phase two-stage MI systems [15]. However, the capacitance of a film capacitor is less than that of an E-cap with the same power rating, which increases voltage ripple at the 2nd harmonic frequency on the DC bus and can have three serious side-effects.…”
Section: Introductionmentioning
confidence: 99%