2006
DOI: 10.1784/insi.2006.48.8.488
|View full text |Cite
|
Sign up to set email alerts
|

Performance monitoring of geodetic instruments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2009
2009
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 5 publications
0
7
0
Order By: Relevance
“…The third method is a classical one both in geodesy and in general technology [5,[9][10][11]. This method has been very widely used in the past and it requires a highly accurate circular scale and one or more (depending on the measuring method) microscopes (preferably photoelectrical) for the scale readings.…”
Section: Calibration Of the Geodetic Instrumentsmentioning
confidence: 99%
“…The third method is a classical one both in geodesy and in general technology [5,[9][10][11]. This method has been very widely used in the past and it requires a highly accurate circular scale and one or more (depending on the measuring method) microscopes (preferably photoelectrical) for the scale readings.…”
Section: Calibration Of the Geodetic Instrumentsmentioning
confidence: 99%
“…The test rig constructed operates as usual comparator device -it compares the angular position of the rotary table (6, Fig 1) with the readouts of geodetic instrument (4) mounted on the table. An angular positioning of rotary table of the test rig is performed by the worm-gear drive with the step motor (7). Angular position of the rotary table is determined by photoelectric angle encoder (8).…”
Section: Equipment For Measurementsmentioning
confidence: 99%
“…Normally rotary disk angular positioning by the drive according to pulses from the photoelectric angular encoder is considered as "rough", and the precise angular value is determined by autocollimator and microscope. That way, the test rig is tested and calibrated by means of the installed instruments in it [7,8]. Usual procedure of testing consists of positioning (by the encoder) of rotary disc at a pitch of 30° (due to the number of faces of multiangular prism) in full circle and registering the autocollimator and microscope readings at every position.…”
Section: Equipment For Measurementsmentioning
confidence: 99%
“…Preliminary calculations, based on the research are presented in [11,13] give the result of the combined uncertainty u 2 c ¼ ðh e Þ of the standard angle of p rad determination equal to 0:06 00 . .…”
Section: Traceability Of Angle Measurements and Uncertainty Of Evaluamentioning
confidence: 99%
“…Use of the standard angle created depends on the needs for angle values measurement or angle measuring instrument calibration. For the circular scale calibration, the three microscope method [13] can be used.…”
Section: Traceability Of Angle Measurements and Uncertainty Of Evaluamentioning
confidence: 99%