Performance of columns packed with the new shell particles, Kinetex-C18

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

3
115
0

Year Published

2010
2010
2017
2017

Publication Types

Select...
8
2

Relationship

1
9

Authors

Journals

citations
Cited by 202 publications
(118 citation statements)
references
References 39 publications
3
115
0
Order By: Relevance
“…Likewise, 4Ј-hydroxydiclofenac and 5-hydroxydiclofenac produced identical daughter ions at m/z 266, 230, 194, and 166. For these sample sets, we found that the new shell particle technology provided the highest separation efficiency while maintaining a low chromatography system back pressure (Gritti et al, 2010). Adequate separation of five of the six tested drug-metabolites combinations was achieved, using a single, long default gradient on a Kinetex C18 column.…”
Section: Direct and Quantitative Evaluation Of Mist Using Lc-ms/msmentioning
confidence: 95%
“…Likewise, 4Ј-hydroxydiclofenac and 5-hydroxydiclofenac produced identical daughter ions at m/z 266, 230, 194, and 166. For these sample sets, we found that the new shell particle technology provided the highest separation efficiency while maintaining a low chromatography system back pressure (Gritti et al, 2010). Adequate separation of five of the six tested drug-metabolites combinations was achieved, using a single, long default gradient on a Kinetex C18 column.…”
Section: Direct and Quantitative Evaluation Of Mist Using Lc-ms/msmentioning
confidence: 95%
“…Consequently, extracolumn effects attributed to instrumentation that reduce the measured separation efficiency are more prominent than with standard HPLC columns [1][2][3][4][5][6][7][8][9][10][11]. Similar to previous eras when column technology began to exceed the limitations of commercial equipment [12,13], extra-column band broadening (ECBB) is now seeing increasing attention as an important factor that needs to be accounted for and reduced as much as possible [14][15][16][17][18].…”
Section: Introductionmentioning
confidence: 94%
“…Superficially porous (core/ shell) sub-3 µm silica particles have also been prepared recently. 2,3,7,10,[19][20][21][22][23][24][25][26][27][28][29][30] Nonporous Silica Particles. Nonporous silica particles have been used for quick separation of peptides and proteins.…”
Section: Sub 3 µM Silica Particlesmentioning
confidence: 99%