Performance of grid-voltage synchronization algorithms based on frequency-and phase-locked loop during severe grid fault conditions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 16 publications
0
3
0
Order By: Relevance
“…However, in DC microgrids, synchronization is achieved by controlling inverter functions, such as (a) a reference sine waveform signal, (b) input voltage, and (c) shape and pattern of pulse width in a Pulse Width Modulator (PWM) [3]. The literature shows that for synchronization, the frequency controller [4], the excitation controller [5], nonlinear controllers [6], and Phase-Locked Loop (PLL) techniques [7,8] are used; however, they have shortcomings one way or the other. From the above references, we conclude that most techniques fail to track the phase and frequency of grid voltage during grid faults and other adverse operating conditions.…”
Section: Initial Synchronization Of DC Microgrid With the Utility's Ac Gridmentioning
confidence: 99%
“…However, in DC microgrids, synchronization is achieved by controlling inverter functions, such as (a) a reference sine waveform signal, (b) input voltage, and (c) shape and pattern of pulse width in a Pulse Width Modulator (PWM) [3]. The literature shows that for synchronization, the frequency controller [4], the excitation controller [5], nonlinear controllers [6], and Phase-Locked Loop (PLL) techniques [7,8] are used; however, they have shortcomings one way or the other. From the above references, we conclude that most techniques fail to track the phase and frequency of grid voltage during grid faults and other adverse operating conditions.…”
Section: Initial Synchronization Of DC Microgrid With the Utility's Ac Gridmentioning
confidence: 99%
“…After the initialization step, the algorithm estimates the open circuit voltage of the battery using = − × R, (7) then the number of steps, CRn, by using where T is the time the battery needs to discharge, and then the supplied charge. The literature provides numerous hands-on methods, as well as Python Libraries, and Matlab Block Libraries based open source codes for measuring the varying internal resistance.…”
Section: Inverter Efficiencymentioning
confidence: 99%
“…All of the methods mentioned above use conventional PLL blocks in the control algorithms. Conventional PLL performs well during balanced condition but their performance is not acceptable during unbalanced conditions due to the "Double frequency oscillation" and can be termed as 2ω oscillation [66]- [67]. The 2ω oscillation arises due to the coupling of the positive and negative voltage sequences during unbalanced conditions.…”
Section: ) Frequency Controlmentioning
confidence: 99%