2017 6th International Conference on Clean Electrical Power (ICCEP) 2017
DOI: 10.1109/iccep.2017.8004734
|View full text |Cite
|
Sign up to set email alerts
|

Performance test of a PQ universal compensator through Control Hardware in the Loop simulation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
11
0

Year Published

2018
2018
2021
2021

Publication Types

Select...
4
2

Relationship

1
5

Authors

Journals

citations
Cited by 6 publications
(11 citation statements)
references
References 8 publications
0
11
0
Order By: Relevance
“…The DC side of the bridge is connected to two capacitors connected in series, whose central point is used as neutral point for the circuit. An adaptive hysteresis current band modulation with fixed switching frequency has been considered [1], [2] and [4]. This device is able to satisfy the following compensations: (i) active load filtering, reactive and active power variations compensation, (ii) island operation of sensitive loads, after the detection of a PQ event in the grid and thanks to the static switch operation and a battery storage system, connected to the DC side of the converter.…”
Section: B Shunt Compensatormentioning
confidence: 99%
See 2 more Smart Citations
“…The DC side of the bridge is connected to two capacitors connected in series, whose central point is used as neutral point for the circuit. An adaptive hysteresis current band modulation with fixed switching frequency has been considered [1], [2] and [4]. This device is able to satisfy the following compensations: (i) active load filtering, reactive and active power variations compensation, (ii) island operation of sensitive loads, after the detection of a PQ event in the grid and thanks to the static switch operation and a battery storage system, connected to the DC side of the converter.…”
Section: B Shunt Compensatormentioning
confidence: 99%
“…and Figure 8. 4 ): to limit the line current at 580 A (value defined in accordance with the capability of the device and with the protection relay thresholds), the series compensator injects a voltage to obtain a downstream voltage equal to: 3 Even if grid protections haven't been considered, the fault duration is fixed to consider the transient behavior during the network voltage restoration. 4 The brown line refers to island operating condition.…”
Section: B Low Voltage Grid Faultmentioning
confidence: 99%
See 1 more Smart Citation
“…These events are characterized in terms of residual voltage (RV) and dip duration (DD) as defined by the EN 50160. For these reasons, different works dealing with many aspects concerning voltage dips can be found in literature, regarding compensating solutions [8][9][10], impact on customers [11][12][13][14] and monitoring systems [15,16]. Moreover, in [17,18] adequate indices for quantifying their severity have been proposed.…”
Section: Introductionmentioning
confidence: 99%
“…PQ events have been classified in standard and several PQ conditioning apparatuses have been introduced in order to deal with different phenomena [3]. Installing a single device to deal with single event is not the best idea so, researchers are looking for multifunctional strategies in specific solutions [4] or even more recently to an universal PQ compensator in order to cover most of the PQ events using a single solutions [5]. Among PQ events, voltage sags and rms voltage drifts have been reported as most significant and frequent ones in both MV and LV distribution systems [6], [7].…”
Section: Introductionmentioning
confidence: 99%