2019
DOI: 10.1016/j.talanta.2018.10.077
|View full text |Cite
|
Sign up to set email alerts
|

pH sensing using whispering gallery modes of a silica hollow bottle resonator

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
16
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5

Relationship

0
5

Authors

Journals

citations
Cited by 26 publications
(16 citation statements)
references
References 34 publications
0
16
0
Order By: Relevance
“…developed an optical pH sensor, which can deposit swellable pH‐sensitive polymer particles on the inner surface of the microbottle resonators and monitor the titration curve to determine the changes of pH and RI of particles. The optimal resolution of the device is 0.06 pH units and the response time is 10–15 s . This method provided constructive results for realizing the surface functionalization of resonators in the future.…”
Section: Structure and Application Of Wgmrsmentioning
confidence: 94%
See 2 more Smart Citations
“…developed an optical pH sensor, which can deposit swellable pH‐sensitive polymer particles on the inner surface of the microbottle resonators and monitor the titration curve to determine the changes of pH and RI of particles. The optimal resolution of the device is 0.06 pH units and the response time is 10–15 s . This method provided constructive results for realizing the surface functionalization of resonators in the future.…”
Section: Structure and Application Of Wgmrsmentioning
confidence: 94%
“…With the continuous improvement of WGMRs in optical sensing, many novel geometric structures have appeared in recent years, such as: microdisk, [17,[116][117][118][119][120][121][122][123][124][125] microbubble, [126][127][128][129][130][131][132] microbottle, [133][134][135][136][137][138][139][140][141][142][143][144][145][146][147] microtube, [148][149][150][151][152][153][154][155][156][157][158][159][160] microcylinder, [161][162][163] etc. These new resonators are widely used in the field of phy...…”
Section: Preparation and Application Of Other Types Of Resonatorsmentioning
confidence: 99%
See 1 more Smart Citation
“…For example, poly(N-isopropylacrylamide) (polyNIPA), poly(acrylic acid) (PAA) and poly (allylamine hydrochloride) hydrogels have sensitive pH-response characteristics. [78,117] Calcium alginate hydrogel, hydroxypropyl methylcellulose hydrogel, and polyvinyl alcohol (PVA) hydrogel can be used as humidity sensitive materials for optical fiber humidity sensors. [118][119][120][121] On the other hand, they can be used as matrix to encapsulate or immobilize specific chemicals, luminescent materials or biological receptors for biochemical detection.…”
Section: Polymersmentioning
confidence: 99%
“…b)The relative position between tapered fiber and resonator. Reproduced with permission [78]. Copyright 2019, Elsevier.…”
mentioning
confidence: 99%