After corneal refractive surgery, various techniques to determine the current corneal power should be compared and the value around which results tend to cluster should be relied on to avoid hyperopia after cataract surgery with lens implantation. In those cases where keratometry and refraction before PRK/LASIK are available, the gold standard is still to subtract the change of the SEQ at the corneal plane from the preoperative central keratometric power, although in the present case report the subtraction of 24 % of the SEQ change at the spectacle plane from the measured corneal power value seemed to produce the best result. Pure subtraction of the SEQ change at the spectacle plane from the corneal power value before refractive surgery has to be avoided in eyes with excessive myopia. The most reliable corrected power value should be inserted in more than one modern third-generation formula (such as Haigis, Hoffer Q, Holladay 2, SRK/T) and the highest power IOL should be implanted. In all instances, the cataract surgeon has to make sure that the corrected K-reading is not wrongly re-converted within the IOL power calculation formula used.