Phase Correction of Fourier Transform Ion Cyclotron Resonance Mass Spectra Using MatLab

Abstract: FT-ICR mass spectrometry has been limited to magnitude mode for almost 40 years due to the data processing methods used. However, it is well known that phase correction of the data can theoretically produce an absorption-mode spectrum with a mass-resolving power that is as much as twice as high as conventional magnitude mode, and that it also improves the quality of the peak shape. Temporally dispersed frequency sweep excitation followed by a time delay before detection results in a steep quadratic variation i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

7
88
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
9

Relationship

5
4

Authors

Journals

citations
Cited by 56 publications
(95 citation statements)
references
References 44 publications
7
88
0
Order By: Relevance
“…Thus, FT-ICR mass spectra have conventionally been displayed in magnitude mode, which is independent of phase. As described in detail elsewhere, 3840 broadband phase correction yields an absorption-mode spectrum with significantly higher resolving power and higher mass accuracy (after one zero-fill of the time-domain data) without loss in S/N. Figure 5 illustrates magnitude-mode and absorption-mode spectra for the 57+ charge state for the IgG1k antibody.…”
Section: Resultsmentioning
confidence: 96%
See 1 more Smart Citation
“…Thus, FT-ICR mass spectra have conventionally been displayed in magnitude mode, which is independent of phase. As described in detail elsewhere, 3840 broadband phase correction yields an absorption-mode spectrum with significantly higher resolving power and higher mass accuracy (after one zero-fill of the time-domain data) without loss in S/N. Figure 5 illustrates magnitude-mode and absorption-mode spectra for the 57+ charge state for the IgG1k antibody.…”
Section: Resultsmentioning
confidence: 96%
“…The measurement also benefits from in-source collisional dissociation to remove adducts; implementation of an electrically compensated open cylindrical cell for improved DC potential tunability to reduce destructive shearing force on the ion cloud; 33, 37 and phase correction to yield absorption-mode spectra with significantly higher resolving power. 3840 …”
Section: (Introduction)mentioning
confidence: 99%
“…A handful of specialized groups, including our own, have detected isotopic fine structure of peptides and even proteins, but required considerable time of tuning, long transient times, specialized parameters, and even specialized data processing. 2830 It is therefore noteworthy that the combination of the dynamically harmonized ICR cell (trade name “ParaCell”) 25 and integrated data processing methods for generating phased absorption-mode spectrum 3133 makes the acquisition of such data routine.…”
Section: Resultsmentioning
confidence: 99%
“…The mass spectrum was phase-corrected using the Autophaser 6.0 phase correction software [25][26][27][28][29][30][31][32]. All onedimensional (1D) spectra were first externally calibrated in the solariXControl software (Bruker Daltonics, Billerica, MA, USA) using Agilent ESI-L Low Concentration Tuning Mix (Agilent Technologies, Stockport, United Kingdom), and then internally calibrated against the theoretical m/z values of the ions generated by cholesterol using the quadratic calibration function within Data Analysis 4.0 (Bruker Daltonik GmbH, Bremen, Germany) [33].…”
Section: Control Mass Spectra and Product-ion Spectramentioning
confidence: 99%