Phase-Shift Modulation for a Current-Fed Isolated DC–DC Converter in More Electric Aircrafts

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2

Citation Types

0
7
0

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
2
1

Relationship

2
6

Authors

Journals

citations
Cited by 28 publications
(7 citation statements)
references
References 31 publications
0
7
0
Order By: Relevance
“…In the next control interval k+1 to k+2, the same process is repeated, and the DCS moves to {a, a+Δf, a+2Δf}. The DCS is moving with the working point in the domain as (9). In this control interval, value a+2Δf results in the smallest cost function (ct), therefore, this value is applied at the time instance k+2.…”
Section: A the Operating Principlementioning
confidence: 99%
See 1 more Smart Citation
“…In the next control interval k+1 to k+2, the same process is repeated, and the DCS moves to {a, a+Δf, a+2Δf}. The DCS is moving with the working point in the domain as (9). In this control interval, value a+2Δf results in the smallest cost function (ct), therefore, this value is applied at the time instance k+2.…”
Section: A the Operating Principlementioning
confidence: 99%
“…Therefore, dedicated Energy Storage Systems (ESS) have been usually integrated to coexist with PPLs in the micro-grids through the interface of Dual-Active-Bridge (DAB) converters [6]. Admittedly, DAB topology and its relevant derivatives [9], [10] have drawn considerable attention in the application of DC micro-grids for their salient merits in high frequency galvanic isolation, high voltage step up/down ability and high power conversion efficiency [11]. Apart from that, dynamic performance of the interface converters is also instrumental for powering the PPLs, and this is largely dependent on the control algorithm applied to the interface converters.…”
mentioning
confidence: 99%
“…In the next control interval k+1 to k+2, the same process is repeated, and the DCS moves to {a, a+Δf, a+2Δf}. The DCS is moving with the working point within the domain of (9). In this control interval, value a+2Δf results in the smallest cost function (ct), therefore, this value is applied at the time instance k+2.…”
Section: A the Operating Principlementioning
confidence: 99%
“…In this context, low-voltage/low-power DC loads, as for instance LED lighting, ICT equipment, USB(-C) chargers are powered directly from the DC grid bus and no longer from the conventional AC grid. Other applications where DC systems are being considered are listed: electric vehicles [3], [4], electric aircrafts [5], DC microgrids applying Building Integrated Photovoltaics (BIPV) [6], Battery Energy Storage System (BESS) [7], Fuel Cell (FC) [8] and datacenters [9]. For such implementations, a DC conversion to adapt the DC voltage levels is required, therefore, DC-DC converters with high step-down (HSD) conversion capability are standing out for such applications.…”
Section: Introductionmentioning
confidence: 99%