2019
DOI: 10.1111/pan.13554
|View full text |Cite
|
Sign up to set email alerts
|

Physico‐chemical stability of Plasma‐Lyte 148® and Plasma‐Lyte 148® + 5% Glucose with eight common intravenous medications

Abstract: Summary Background Plasma‐Lyte 148® is a balanced, crystalloid intravenous (IV) fluid which is both calcium‐free and isotonic. It prevents the hyperchloremic metabolic acidosis and iatrogenic hyponatremia seen with use of 0.9% sodium chloride and hypotonic solutions, respectively. However, data on compatibility with commonly used drugs are lacking. Aims To investigate the stability of Plasma‐Lyte 148® and Plasma‐Lyte 148® + 5% Glucose with eight commonly used therapeutic agents when compared with 5% glucose an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(9 citation statements)
references
References 16 publications
0
9
0
Order By: Relevance
“…Dawson et al studied the compatibility of ketamine 0.2 mg/ml (1 + 30) with the buffered electrolyte solution and concluded that the mix was physically compatible in the mixing ratio of 1 + 30 18 . Baxter Medical concluded that equal parts of ketamine 2 mg/ml and the buffered electrolyte solution to be physically compatible 19 .…”
Section: Discussionmentioning
confidence: 99%
See 4 more Smart Citations
“…Dawson et al studied the compatibility of ketamine 0.2 mg/ml (1 + 30) with the buffered electrolyte solution and concluded that the mix was physically compatible in the mixing ratio of 1 + 30 18 . Baxter Medical concluded that equal parts of ketamine 2 mg/ml and the buffered electrolyte solution to be physically compatible 19 .…”
Section: Discussionmentioning
confidence: 99%
“…Three studies investigating the intravenous compatibility of the same buffered electrolyte solution and the buffered electrolyte‐glucose solution with one‐drug‐at‐a‐time have been published. These studies reported concentration dependent compatibility between midazolam and the two buffered electrolytes, irrespective of whether glucose was present 17–19 . Hammond et al 17 investigated physical compatibility by visual inspection and reported that precipitation formed immediately when mixing three parts of midazolam 3 mg/ml with two parts of the buffered electrolyte solution or the buffered electrolyte‐glucose solution.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations