2004
DOI: 10.1016/j.ejpb.2004.02.011
|View full text |Cite
|
Sign up to set email alerts
|

Physicochemical characterisation of cationic polybutylcyanoacrylat-nanoparticles by fluorescence correlation spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
7
0

Year Published

2006
2006
2022
2022

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 28 publications
1
7
0
Order By: Relevance
“…The improved activity of drug-loaded NPs presented here highlights the relevance of this class of delivery system for leishmaniases. The PBCA-NFOH-NPs z-average (151.5 ± 61.97 nm) was similar to those obtained by Weyermann et al and Sommerfeld et al [13,14], who reported a z-average equal to 130-140 nm and 164-326 nm, respectively. The size of the NP determines its targeting abilities such as cell uptake.…”
Section: Discussionsupporting
confidence: 89%
“…The improved activity of drug-loaded NPs presented here highlights the relevance of this class of delivery system for leishmaniases. The PBCA-NFOH-NPs z-average (151.5 ± 61.97 nm) was similar to those obtained by Weyermann et al and Sommerfeld et al [13,14], who reported a z-average equal to 130-140 nm and 164-326 nm, respectively. The size of the NP determines its targeting abilities such as cell uptake.…”
Section: Discussionsupporting
confidence: 89%
“…Many equipment designed for DLS may also have an attachment for electrophoretic light scattering to measure the zeta-potential important for colloids stability. An interesting variation of DLS is the fluorescence correlation spectroscopy (FCS) (102). FCS is a well-established technique to determine diffusion coefficient, size and mass of particles, as well as to characterize the binding of low molecular weight ligands to larger receptor molecules in solution.…”
Section: Dynamic Light Scattering (Dls)mentioning
confidence: 99%
“…Due to its very high sensitivity and selectivity 13 the FCS technique has found numerous applications in fields ranging from cell biology 14,15 to polymer, colloid, and interface science 1620 . FCS is perfectly suited for studying the formation of NCs 21,22 , their drug loading 23,24 , stability 2527 , interactions with plasma proteins 2832 and triggered release 33,34 . However, FCS has so far never been adapted to in situ blood measurements.…”
Section: Introductionmentioning
confidence: 99%