2011
DOI: 10.1016/j.nima.2010.11.189
|View full text |Cite
|
Sign up to set email alerts
|

Pixel array detector for X-ray free electron laser experiments

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
55
0
1

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 108 publications
(56 citation statements)
references
References 4 publications
0
55
0
1
Order By: Relevance
“…By varying the intensity of the drive laser it was possible to obtain shock pressures of 37±2 to 253±6 GPa, as measured via position of the Bragg peaks considering volumetric compression of the crystal lattice together with the Rankine-Hugoniot equations using the shock speed data [46]. The LCLS beam (9.6 keV, 50 fs duration) probed the compressed region after a set delay (from just before to ∼10 ns after shock break out) and the resulting diffraction patterns were captured on a number of CSPAD detectors (Cornell-SLAC Pixel Array Detector) [47]. The target was oriented such that the surface normal was aligned at an angle of 35…”
mentioning
confidence: 99%
“…By varying the intensity of the drive laser it was possible to obtain shock pressures of 37±2 to 253±6 GPa, as measured via position of the Bragg peaks considering volumetric compression of the crystal lattice together with the Rankine-Hugoniot equations using the shock speed data [46]. The LCLS beam (9.6 keV, 50 fs duration) probed the compressed region after a set delay (from just before to ∼10 ns after shock break out) and the resulting diffraction patterns were captured on a number of CSPAD detectors (Cornell-SLAC Pixel Array Detector) [47]. The target was oriented such that the surface normal was aligned at an angle of 35…”
mentioning
confidence: 99%
“…Bragg intensities were calculated from the published CIF and PDB files using the programs iotbx.cif of cctbx (Gildea et al, 2011) and SFALL of CCP4 (Agarwal, 1978), respectively. The images were simulated assuming the tiled CSPAD detector geometry of the Linac Coherent Light Source (LCLS) (Hart et al, 2012;Philipp et al, 2011). The resolution of each case was chosen to reflect experimentally realistic conditions.…”
Section: Simulated Datamentioning
confidence: 99%
“…The detector is made of 32 silicon sensors 500µm thick bumpManuscript received November 16, 2012. SLAC- PUB-15277bonded to 64 185x194-pixel ASICs tiled to cover a square approximately 17 cm by 17 cm [1], [2], [3], [4]. The CSPAD camera has experienced radiation damage whose symptoms fall into several categories.…”
Section: Introductionmentioning
confidence: 99%