1981
DOI: 10.1016/0022-4731(81)90010-8
|View full text |Cite
|
Sign up to set email alerts
|

Plasma concentration gradient of steroid hormones across human mammary tumours in vivo

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
16
0

Year Published

1987
1987
2005
2005

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 65 publications
(16 citation statements)
references
References 14 publications
0
16
0
Order By: Relevance
“…For E2 estimations, the ultrasensitive system was used. The results of these assays were compared with the results obtained with other commercial immunoassays, which in turn had been validated by comparison with in-house immunoassays, making use of steroid extraction and purification by column chromatography (testosterone (16), E2 (17), androstenedione (18), E1 (19) and DHEAS (20)). The same procedure was used for SHBG, where the in-house method used ammonium sulphate precipitation (21).…”
Section: Hormone Measurementsmentioning
confidence: 99%
“…For E2 estimations, the ultrasensitive system was used. The results of these assays were compared with the results obtained with other commercial immunoassays, which in turn had been validated by comparison with in-house immunoassays, making use of steroid extraction and purification by column chromatography (testosterone (16), E2 (17), androstenedione (18), E1 (19) and DHEAS (20)). The same procedure was used for SHBG, where the in-house method used ammonium sulphate precipitation (21).…”
Section: Hormone Measurementsmentioning
confidence: 99%
“…The ether was evaporated and the residue dissolved in an assay buffer. The characteristics of the antiserum used are given by VAN LANDEGHEM et al (1981). The immunoassay procedure was similar to the one described for ~:ortisol, except that preincubation with antiserum was not performed.…”
Section: Hormone Analysismentioning
confidence: 99%
“…Estrone (El) and 17P-estradiol (E2) were determined by radioimmunoassay after plasma extraction with ether and after purification and separation by chromatography on Sephadex LH-20 columns with toluenemethanol 9223 as eluant (Van Landeghem, 1981). Androstenedione (Adione) was measured by radioimmunoassay after plasma extraction with diethylether (Van Landeghem, 1981).…”
Section: Hormonal Assaysmentioning
confidence: 99%
“…Androstenedione (Adione) was measured by radioimmunoassay after plasma extraction with diethylether (Van Landeghem, 1981).…”
Section: Hormonal Assaysmentioning
confidence: 99%