“…This modification reduced the relative standard deviation (RSD) of the Mg I 285.21 nm line in an aluminum magnesium alloy from 33% to 18%. 15 However, these methods require complex equipment and have restricted stability improvements. Consequently, researchers initiate their investigation by analyzing the data and subsequently refining the obtained spectra to enhance their reliability and consistency.…”
Laser-induced breakdown spectroscopy (LIBS) has faced a notable obstacle in the presence of substantial spectral fluctuations, hindering its progress and prompting researchers to prioritize resolving this complex problem. Considering the...
“…This modification reduced the relative standard deviation (RSD) of the Mg I 285.21 nm line in an aluminum magnesium alloy from 33% to 18%. 15 However, these methods require complex equipment and have restricted stability improvements. Consequently, researchers initiate their investigation by analyzing the data and subsequently refining the obtained spectra to enhance their reliability and consistency.…”
Laser-induced breakdown spectroscopy (LIBS) has faced a notable obstacle in the presence of substantial spectral fluctuations, hindering its progress and prompting researchers to prioritize resolving this complex problem. Considering the...
“…[1][2][3][4][5] However, the limited measurement repeatability of the system hinders its quantitative analytical performance. Various methods have been developed to improve spectral stability, such as beam shaping, 6 optimization of laser focusing optics, [7][8][9][10] plasma image assistance, 11 algorithm correction, 12,13 etc.…”
Spectral stability improvement through various wide fields of view collecting optics, averaging temperature and ionization conditions, reducing the impact of plasma morphology fluctuations on acquisition.
“…The first one is to improve the experimental equipment or environment. For example, Hou et al 12 improved the LIBS signal quality by shaping the laser beam from a commonly used Gaussian profile to a flat-top profile. Yao et al 13 reported that aberration diminished focusing shrunk the laser focal region, leading to fewer plasma position fluctuations and higher signal repeatability.…”
Large spectral fluctuations bring large errors in laser-induced breakdown spectroscopy (LIBS) analysis, which impedes the improvement of precision and accuracy, limiting the large-scale application and commercialization. In this work, we...
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.